DI/DO Sel.
3
4
5
F
14
20 to 2F
50
51
52
53
54
56
79
0
6
E
F
50
51
YASKAWA ELECTRIC YEG-TOEP-C710606-50A-1-0YaskawaACDrives-L1000VQuickStartGuide
Digital Input Function Selections
Multi-step speed reference 1
Multi-step speed reference 2
Multi-step speed reference 3
Through mode (Set when a terminal is not used)
Fault reset (Reset when turned ON)
External fault; Input mode: N.O. contact / N.C. contact Detection mode:
Normal/during operation
Nominal speed (d1-19)
Intermediate speed (d1-20)
Releveling speed (d1-23)
Leveling speed (d1-26)
Inspection operation
Motor contactor feedback
Brake feedback
Digital Output Function Selections
During Run (ON: Run command is ON or voltage is being output)
Drive Ready
Fault
Not used (through mode)
Brake Control
Output Contactor Control
Description
7 Parameter Table