38YY...G / 38YYS...G
Electrical connections
L N
R
L N R C Y
» ¿
L
R-410A
Heat pump unit
C Y O
W
S
2
O
W
S
2
Heat pump system
³
R
C
Y O
W
S
2
O W
S
N
R
C Y
2
·
Terminal box legend
Earth.
L
Live power supply.
N
Neutral power supply.
R
Live connection indoor/outdoor unit.
C
Neutral connection indoor/outdoor unit.
Y
Compressor interlocking contact.
O
Reversing valve control.
W2 Outdoor fan signal.
S
Defrost end signal.
10
120
10 100
Mains supply connecting cable
(field wiring).
Connecting cable, indoor-outdoor units
(field wiring).
³ Indoor unit
· Outdoor unit
» Main switch
¿ Time-delay fuse or circuit breaker
(see table VI "Electrical data").