Installing The Indoor Unit - Mitsubishi Electric PKA-A·FA Installation Manual

Hide thumbs Also See for PKA-A·FA:
Table of Contents

Advertisement

3. Installing the indoor unit

A24, A30
A
Min.6-1/2
A36
A
Min.6-1/2
Fig. 3-4
1
A
Fig. 3-6
B
2
A
B
C
Fig. 3-8
E
5
4
3
2
1
Fig. 3-9
4
H
J
Fig. 3-10
4
Max.19/32
Min.2-3/8
B
Min.19-11/16
Fig. 3-5
Min.2-3/8
Min.19-11/16
C
Fig. 3-7
3
D
F
G
I
K
G
H
I
(inch)
3) Installing the wall mounting fixture
Since the indoor unit weighs near 30 kg, 66 lbs, selection of the mounting
location requires thorough consideration. If the wall does not seem to be
strong enough, reinforce it with boards or beams before installation.
The mounting fixture must be secured at both ends and at the centre, if
possible. Never fix it at a single spot or in any nonsymetrical way.
(If possible, secure the fixture at all the positions marked with a bold arrow.)
(Fig. 3-4)
Secure the wall mounting fixture through its middle row of 12-mm, 1/2
inch-dia. holes using locally purchased bolts (through bolts, bolt anchor
C
and nut anchor) of M10 or W3/8 threading. The bolt tip must not protrude by
more than 15 mm, 9/32 inch from the wall surface. (Fig. 3-5)
Use at least two bolts for a concrete wall, and at least four bolts for a foamed
concrete wall.
A Wall-fixing bracket
Warning:
If possible, secure the fixture at all the positions marked with a bold arrow.
Caution:
The unit body must be mounted horizontally.
3.3. Preparation for piping connection
Remove the vinyl band that holds the drain piping.
• This vinyl band can be used to temporarily attach the pipes to the wall mounting
fixture while connecting the left pipe.
1) Rear, right and lower piping (Fig. 3-6)
1 Remove the right side panel.
2) Left and left rear piping
1 Remove the side panel.
When embedding pipes into the wall (Fig. 3-7)
When the refrigerant pipe, drain pipes, internal/external connection lines, etc., are to
be embedded into the wall in advance, the extruding pipes, etc., may have to be bent
and have their length modified to the unit.
• Make the pipes to be embedded slightly longer than necessary, and install.
A Right side panel
D
B Through hole
2 Remove the five screws indicated by the arrows in the diagram. (Fig. 3-8)
3 Remove the left side panel, then the lower panel.
1. While pushing up the front lower portion of the side panel (to disengage the side
panel catch from the unit catch), slide the upper portion of the side panel to the
left.
D
• When the indoor unit is already mounted, be sure the unit does not fall from the wall
mounting fixture.
• For reassembly, put the catch at the front lower portion of the side panel over the
unit body and push it to the right.
A Grille
B Left side panel
C Lower panel
∗ Structure of the side panel and the unit body (Fig. 3-9)
1. Panel catch engages the unit body catch.
2. Panel catch is put in the unit body hole.
3. Panel catch engages the unit body catch.
4. Sheet metal of the unit body enters the panel.
5. Panel catch enters the unit body hole.
4 The drain hose can be connected at two different positions. Use the most conven-
ient position and, if necessary, exchange the position of the drain pan, rubber plug
and the drain hose. (Fig. 3-10)
G Drain pan
H Band
I Plug
J Drain hose
K Screwdriver
K
B Mounting bolt
C Wall
C On-site piping
D Wall-fixing bracket 1
D Catch
E Side panel
F Unit body