Installation Location; Installing The Indoor Unit - Mitsubishi Electric PKA-A·FA Installation Manual

Hide thumbs Also See for PKA-A·FA:
Table of Contents

Advertisement

2. Installation location

B
Fig. 2-1

3. Installing the indoor unit

1
2
4
5
7
8
0
q
Fig. 3-1
■ A24, A30
A
38-31/32
13/32×3-19/32= (35-13/16)
35-7/16
B
23/32
23/32
D
E
8-27/32
9-7/16
7-3/32
7-3/32
F
H
■ A36
G
50
1/2×3-19/32=(46-9/16)
23/32
23/32
D
B
E
11-5/8
8-27/32
9-71/16
H
F
Fig. 3-2
A
C
Fig. 3-3
A
D
E
W
3
6
9
9-21/32
17-29/32
11-7/32
3/4
G
C
3-19/32
11-1/32
12-3/8
24-1/32
3-17/32
I
A
9-21/32
23-7/16
11-7/32
35-7/16
3/4
C
3-19/32
7-3/32
11-1/32
12-3/8
29-17/32
3-17/32
H
I
B
E
D
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
Select a proper position allowing the following clearances for installation and mainte-
nance.
C
H
Models
W
1400
A24, A30
55-1/8
1680
A36
F
66-5/32
Warning:
Mount the indoor unit on a ceiling strong enough to withstand the weight of the
unit.
2.2. Outline dimensions (Outdoor unit)
Refer to the outdoor unit installation manual.
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories.
PARTNUMBER
1
Wall-fixing bracket
2
Tapping screw 4 × 35
3
Insulation material
4
Band
5
Felt tape
6
Drain socket
7
Wireless remote controller
8
Remote controller holder
9
Alkali batteries
0
Wired remote controller
q
Drain adaptor
7 7 7 7 7 - 9 9 9 9 9 are stored in a cut-out section of the packing material (styrofoam).
(inch)
3.2. Installing the wall mounting fixture (Fig. 3-2)
1) Setting the wall mounting fixture and piping positions
Using the wall mounting fixture, determine the unit's installation position
and the locations of the piping holes to be drilled.
Warning:
Before drilling a hole in the wall, you must consult the building contractor.
A Indoor unit center line
B Left drain range
C Right drain range
D Hole for tapping screw
E Bolt hole
F Hole for tapping screw
G Contour of the unit
H Knockout hole for left rear piping
I Rear piping access hole (90-100 mm, 3-9/16 to 4 inch dia.)
2) Drilling the piping hole (Fig. 3-3)
Use a core drill to make a hole of 90-100 mm, 3-9/16 to 4 inch diameter in the
wall in the piping direction, at the position shown in the diagram to the left.
The hole should incline so that the outside opening is lower than the inside
opening.
Insert a sleeve (with a 90 mm, 3-9/16 inch diameter and purchased locally)
through the hole.
Note:
The purpose of the hole's inclination is to promote drain flow.
A Sleeve
B Hole
C (Indoors)
D Wall
E (Outdoors)
D
H
A
B
C
235
340
Min. 150
Min. 50
Min. 30 Max. 250 Max. 150
9-1/4
13-3/8 Min. 5-15/16
Min. 2
Min. 1-3/16 Max. 10 Min. 5-15/16
235
340
Min. 150
Min. 50
Min. 30 Max. 250 Max. 150
9-1/4
13-3/8 Min. 5-15/16
Min. 2
Min. 1-3/16 Max. 10 Min. 5-15/16
ACCESSORY
QUANTITY
1
12
2
4 (large) + 5 (small)
3
1
1
1
2
1
1
(mm)
(inch)
E
F
LOCATION OF SETTING
Fix at the back of the unit
Set inside the unit
}
for PKA-A·FAL
for PKA-A·FA
3