Maintenance and service
6.7

Diagnostic menu

1. Press ON/OFF button to turn off the appliance.
2. Press and hold "Program"
ON/OFF button to turn appliance ON.
3. Release the
button when '188' appears on the
display. The display should read 'P2' when the
program button is released. If not, repeat process.
4. Press and release the
panel until the display reads 'P4'. You are now in the
diagnostic mode of the control board.
5. When the display reads 'P4', press and release the
button once again and the display should read
'E'.
6. Use the
and
cycle through different diagnostic modes available.
7. Once in the selected diagnostic mode of your
choice, press and release the
the diagnostic information.
B EXAMPLE: to read the flow rate in gallons per minute
while the unit is flowing water, cycle to the '3d' mode
and press the
button. A reading of 25 on the
display would indicate the heater is reading a flow
rate of 2.5 gallons/minute.
B Once the information is obtained, press the
button again to return to the diagnostic mode menu
and scroll to addition diagnostic information.
8. Press ON/OFF button to turn OFF the appliance and
back ON again to return heater to normal function.
Diagnostic menu
E
Entry/Exit into sub-modes
0d
Set-point temperature
1d
Inlet water temperature (°F)
Outlet water temperature (°F)
2d
3d
Water flow (gallons/min)
4d
Gas type (LP or NG)
5d
Fan speed (Hz)
6d
Burner power (%)
7d
Maximum power (kW)
8d
Back flow temperature (°C)
9d
Exhaust temperature (°C)
1F
Most recent error/failure
2F
2nd most recent error
3F
3rd most recent error
4F
4th most recent error
5F
5th most recent error
6F
6th most recent error
Table 26
46
button and press
button on the control
buttons on the control unit to
button to display
7F
7th most recent error
8F
8th most recent error
9F
9th most recent error
10th most recent error
10F
H0
Numbers of hours - mode 0
H1
Numbers of hours - mode 1
H2
Numbers of hours - mode 2
Table 26
6.7.1
Working hours
To see how many hours the appliance has worked,
please enter the "Diagnostic menu" (chapter 6.7);
B Select the sub-mode "H0".
Write the number that shows in the display.
B Select the sub-mode "H1".
Write the number that shows in the display.
B Select the sub-mode "H2".
Write the number that shows in the display.
After checking the sub-modes H0, H1 and H2, intro-
duce the values in the table below;
Working hours
Number in H0
______
Number in H1
______ (X 100) =
Number in H2
______ (X 10 000) =
(H0 + H1 + H2) = Total of hours
Table 27
Example:
Calculation of number of working hours,
Working hours
Number in H0
60
Number in H1
5
(X 100) =
Number in H2
0 (X 10 000) =
(H0 + H1 + H2) = Total of hours
Table 28
_______ +
_______ +
_______ +
_________
60
+
+
500
+
0
560
6 720 644 887

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents