10.7 UNITS TEMPERATURES
This function enables the temperatures of each single unit
to be set.
The display shows the following:
Unit 2 temp.
XXX°C
where 2 represents the number corresponding to the unit,
XXX is a value selectable from 80÷125°C in 1°C steps.
Press keys T8 if the parameter needs to be changed.
Press key T9 to proceed to the next setting.

10.8 PID TYPE THERMOSTAT CONTROL

This function enables the PID thermostat control parameters
to be parameterised. This function is not currently operatio-
nal. A recommendation is made not to change the pre-set
parameters.
The display shows the following:
kP
kI
XX.X
Y.YY
where XX.X is the proportional correction constant;
Y . Y Y i s t h e i n t e g r a t e d c o r r e c t i o n c o n s t a n t ;
Z Z . Z i s t h e d e r i v a t i v e c o r r e c t i o n c o n s t a n t .
P r e s s k e y T 9 t o p r o c e e d t o t h e n e x t s e t t i n g .

10.9 PID CONTROL

This function enables the PID control range to be set compa-
red to the set point temperature. This function is not currently
available. A recommendation is made not to change the
pre-set parameters.
The display shows the following:
PID control
X°C
Pressing key T9 enables the next setting to be accessed.

10.10 FILLING TIME-OUT

This function enables the pump's continuous operating time
to load the water level in the boiler to be set.
The display shows the following:
Filling Time-Out
XXX
where XXX represents the selectable time expressed in seconds.
The selectable value ranges between 10÷250 in 1 sec steps.
58
kD
ZZ.Z
Press keys T8 if the parameter needs to be changed.
Pressing key T9 enables the next setting to be accessed.
WARNING!:
the machine is pre-set with a value equal
to 120 sec. A recommendation is made not to exceed this
value when the settings are changed, because the pump
could overheat after more than 120 secs
The "TECHNICAL PROGRAMMING" function can be exited
by pressing key T9.
11 - UNITS TEMPERATURES
TECHNICAL DISPLAY
11.1 MODEL. "D"
The machine includes a procedure to display the temperatures
actually measured by the probes for each unit. First of all the
machine must be switched off using the main power switch,
then press key T2 and key T4 and at the same time switch the
machine On using the main power switch to access this menu.
Wait until the display becomes active while continuing to
press the keys:
XXX° XXX° XXX° XXX°
where XXX represent the temperatures measured by the units
probes (the figures are read from left to right).
The temperatures of the third and fourth unit will be represen-
ted by the symbols "- - -" in the case of a machine with 2 units.
This system can be used to monitor the actual operation of
the probes and the exact calibration.
The machine can operate normally when this display mode
is used.
NOTE: the fluctuating trend of the readings is clearly a
normal situation.
The machine must be switched off and then switched on
using the main power switch to exit this menu.
hh:mm