Mounting The Water Heater To The Wall - Navien NPE-180A Installation Manual

Condensing
Hide thumbs Also See for NPE-180A:
Table of Contents

Advertisement

Adequate installation clearances
Install the water heater in an area that allows for service and
maintenance access to utility connections, piping, filters, and traps.
Based on the installation location, ensure the following clearances
are maintained:
Clearance
Indoor Installation
from:
9 inches (229mm)
Top
minimum
0.5 inches (20mm)
Back
minimum
4 inches (100mm)
Front
minimum
3 inches (76mm)
Sides
minimum
12 inches (300mm)
Bottom
minimum
Clean, debris and chemical-free combustion air
Do not install the water heater in areas where dust and debris
may accumulate or where hair sprays, spray detergents, chlorine,
or similar chemicals are used.
Do not install the water heater in areas where gasoline or other
flammables are used or stored.
Ensure that combustible materials are stored away from the
water heater and that hanging laundry or similar items do not
obstruct access to the water heater or its venting.
In commercial locations, do not install the water heater in areas
with greasy fumes or heavy amounts of steam or take measures
to prevent fumes and steam from entering the water heater.
High Elevation Installations
This water heater may be installed at elevations up to 10,100 ft
(3,078 m) for use with Natural Gas and 4,500 ft (1,370 m) for
use with Propane. Refer to "3.8.2 Setting the Front Panel DIP
Switches" on page 34 for the appropriate altitude setting.
14
Installing the Water Heater
Outdoor Installation
36 inches (900mm)
minimum
0.5 inches (20mm)
minimum
24 inches (600mm)
minimum
3 inches (76mm)
minimum
12 inches (300mm)
minimum

3.2 Mounting the Water Heater to the Wall

Navien water heaters come with an upper mounting bracket that is
pre-drilled at 16 inches on center for easy installation on standard
wall studs. If the strength of the wall is insufficient or if the framing
is non-standard or uneven, reinforce the area before installing the
water heater. Avoid installation on common walls as the unit will
make some operational noises while it is running.
To mount the water heater to the wall:
1.
Affix the bracket securely to the wall and ensure that it is level
and that it can support the weight of the water heater.
2.
Align the grooves on the back of the water heater with the
tongues on the mounting bracket and hang the water heater
on the bracket.
When mounted with the mounting bracket, the water heater
will have a 5/8" (16mm) clearance from the back of the wall.
CAUTION
Do not mount the water heater to dry wall that has not been
reinforced.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Npe-240sNpe-210aNpe-240aNpe-210sNpe-180s

Table of Contents