INSTALLATION
OFAPPLIANCE
CONNECTING
APPLIANCE TOGASSUPPLY
Theinstallation o f this appliance must c onform with local c odes or,inthe
A TRAINED SERVICEMAN O RGASAPPLIANCE I NSTALLER MUST
absence of local codas,with the National F uel Gas Code,ANSI
MAKETHEGASSUPPLYCONNECTION.Leaktastingoltheappliance
Z223.1 -Latest E dition, or,inCanada, CAN/CGA-B149
Installation Code,
shall be conducted by the installeraccording to the instructions
latestEdition.
given.
This appliance, when installed, m ust be electrically g rounded in
1. IF NOOTHERAPPLIANCE IS TO BEINSTALLED BELOW THIS
accordance withlocal c odes or,intheabsence o f local c odes, withthe
COOKTOP
National Electrical Code ANSI/NFPA N o.70-latestEdition, or,inCanada,
Join theappliance pressure regulator supplied withthisappliance tothe
current CSAStandard C 22.1 Canadian Electrical Code, P art1.
entrance t hreads o ftheGas Manifold. Theappliance regulator ismarked
with a directional arrow indicating correct direction of gas flow. E nsure t he
Allsupply piping, except a s noted, s hould usecommon National Pipe
appliance regulator is installed withthearrow pointing t oward thegas
Thread (N.P.T.). F orall pipeconnections usean approved p ipejoint
manifold e ntrance. Tighten theappliance regulator to20 to30 ft-lbs of
compound rasistant totheaction ofLP gas.
torque.
CAUTION: Warranty isvoid onJenn-Air equipment installed o ther t han as
I
IMPORTANT
recommended bymanufacturer.
I Never t ighten t omore than 35ft-lbs oftorque. Always useanapproved
Thisappliance is designed f or usewiththe appliance g aspressure
pipe joint c ompound rasistant totheaction ofLPgas.
regulator supplied with thisappliance. Itmustbeinstalled inthegasway
Install t heappliance initscounter cutout.
ahead ofthegasmanifold entrance. Itispreset foruse with natural gas and
must b e converted, as described onpage 6, forusewithLPgas.(See
Makethegasconnection totheinlet of theappliance pressure regulator
figures 1 0and11 .)
with 1/2"malepipe threads.
Thisappliance isdesigned tooperate at a pressure of 5 inches o fwater
Installa manual shut-off valvein anaccessible location i n thegasline
column o n natural gasor,if converted forusewithLPgas(propane or
ahead oftheappliance pressure regulator and externaltothis appliaoce for
butane), 10inches w ater c olumn. Make sure this appliance issupplied with
thepurpose ofturning o norshutting offgastotheappliance.
andadjusted f or thetypeofgasfor which it isdesigned.
Make additional pipe connections
asnecessary ahead oftheshut-off valve
This appliance wasadjusted a tthefactory foruse with natural gas. I f,atany
tothegassupply s ource. Assure allpipe joint c onnections
aregastight.
time, t hisappliance i stobe used witha different typeof gas,all ofthe
conversion adjustments described onpages 5 and7 mustbe made bya
IMPORTANT
qualified s ervice t echnician before attempting tooperate t hecooktop o n
Apply a non-corrosive
leakdetection fluid toalljoints andfittings i nthe
that g as. N atural gasshould b esupplied tothe appliance pressure regulator
gasconnection between t hesupply lineshut-off valveandtherange.
ata line pressure between 6 and14inches o fwater c olumn o r,ifconverted
Include g as fittings a nd joints intherange ifconnections
were disturbed
forIF'gas,between 1 1and14 inches,
during i nstallation. Check forleaks! B ubbles appearing a round f ittings
and connections
willindicate a leak. I f a leak appears, turnoffsupply line
WARNING:
If the line pressure supplying the appliance p ressure
gasshut-off valve, t ighten c onnections,
turnonthesupply l ine gasshut
regulator exceeds 1 4"W.C.(anygas), a n external regulator must b eI
offvalve, a ndretest f orleaks. N ever t estforgas leaks with an open
installed i nthegaslineahead oftheappliance regulator toreduce t heI
flame.
pressure to nomore than14"W.C. Failure t o do thiscanresult i n
malfunction and damage t otheapplance.
ILLUSTRATIVE GAS SUPPLY PIPING
(NO OTHER APPLIANCE BELOW COOKTOP)
I
BURNER BOX
Insure thisappliance isadjusted f orthetype ofgassupplied toitand that
_
(REAR OFAPPLIANCE)
thegassupply pressure totheappliance r egulator iswithin theproper
pressure range.
I
I
• If thisisa 36"widemodel, orif it isa 30"widemodel andnoother
I I _
MANIFOLD
I_, _
ENTRANCE
appliance is to be installed in the cabinetry b elow it, proceed a s
instructed under p aragraph I.
_
APPLIANCE
• If thisisa 30"widemodel anda Jenn-Alr Model W 30XXX orW131
__
PRESSURE
Electric W allOvenis to be installed in cabinetry b elow, proceed a s
REGULATOR
instructed u nder p aragraph II.
I
/
• Donotremove p rotective capfrom pipestub atmanifold entrance until
_
ALLPIPEJOINTS
ready tojoin gassupply p iping toappliance.
_
1/2 N.P.T.
MANUAL
SHUTOFF
NOTE: I n Canada, gasutilization codas prohibit useofstreet e lbows. Use
VALVE
standard pipeelbows andmakemodifications