4.2.2

Sensor connections

Figure 4-2
4.3

Sensor Module Cabinet 10 (SMC10)

4.3.1

Description

The cabinet-mounted sensor module 10 (SMC10) evaluates sensor signals and transmits
the speed/position, rotor position and, if necessary, the motor temperature via DRIVE-CLiQ
to the control unit.
The SMC10 is used to evaluate sensor signals from resolvers.
The maximum signal cable lengths are:
• For 2-pin resolver: 130 m
• For multi-pin resolver: 50 m
The module may be snapped on to a DIN50022 mounting rail.
Equipment Manual for Control Units and Additional System Components
Equipment Manual, (GH1), 04.2004 Edition, 6SL3097-2AH00-0BP0
Sensor connection via SMC (Sensor Module Cabinet)
DRIVE-
CLiQ
SMC
Motor
Module
Sensor connection
Sensor System Connection
4.3 Sensor Module Cabinet 10 (SMC10)
Signal cable
Power cable
E
M
ϑ
~
3
Motor
4-3