8.3.3 Electrical Rating

The FortiSwitch-1000's electrical ratings should be considered when connecting to the power
supply circuits. Consideration must be given to the effect that overloading of circuits may have on
overcurrent protection and supply wiring.

8.3.4 Grounding

Reliable earthing (grounding) of the FortiSwitch-1000 chassis through the protective earthing
terminal(s) should be maintained.

8.3.5 Metallic Interfaces

FortiSwitch-1000 metallic interfaces are suitable for connection to intrabuilding or non-exposed
wiring or cabling only.

8.3.6 Fuse Replacement

Although FortiSwitch-1000 field-replaceable units (cards, power supplies and fan trays) are
provided with fuses and holders, Fortinet does not recommend replacement of damaged or blown
fuses. It is recommended instead that the entire FRU be returned to Fortinet for
repair/replacement if found to be non-functional.

8.3.7 LASER Safety

CLASS 1 LASER PRODUCT: FortiSwitch-1000 circuit boards may be equipped with optical
communication transmitters which have been evaluated and found to be in compliance with
requirements found within 21 CFR (FDA-CDRH) and EN 60825-1 for Class 1 laser devices.
WARNING: While Class 1 laser products are considered to be "eye safe" without the need for
additional protection, when working around the circuit boards, the following general safety
guidelines should be observed to reduce the risk of eye injury:
Do not look or stare into unterminated optical fiber ports or at fibers that are connected to a
source.
Do not examine unterminated optical fiber ports or optical fibers that are connected to a source
with optical instruments. The use of optical instruments (e.g. magnifying glass) with this product
may increase eye hazard.
Adjustments/settings, maintenance, operational parameters and procedures other than those
specified and allowed herein and on the rating plate of the FortiSwitch-1000 may result in
increased eye hazard.
Do not attempt to perform any repair or maintenance on optical communications components.
Repairs and maintenance outside that which is allowed herein must be performed only by an
authorized repair facility.

8.3.8 Restricted Access Location

The FortiSwitch-1000 is intended to be installed only in a RESTRICTED ACCESS LOCATION.
A RESTRICTED ACCESS LOCATION is defined as an area where access can be gained only by
SERVICE PERSONNEL who have been instructed about the reasons for the restrictions applied
to the location and about any precautions that must be taken.