Power/Timer
Status Indicator
Indicator
Off
Off
Off
Off
Blinking Red
Off
3. Error Code Operational Check
Note: The TV must be in "Shut Down" and not have been switched Off, to perform the Error Code Opera-
tional Check. When the TV is switched Off, the code automatically resets to "12" No Error.
Pressing the front panel "DEVICE" and "MENU" buttons at the same time, and holding for 5 seconds,
activates the Error Code Mode. The LED flashes denoting a two digit Error Code, or indicating no problem
has occurred since the last Initialization.
Note: The front panel buttons must be used, NOT those on the Remote Control.
The number of flashes indicates the value of the MSD (tens digit) of the Error Code.
The flashing then pauses for approximately 1/2 second.
The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
The Error Code is repeated a total of 5 times.
Example: If the Error Code is "23", the LED will flash two times, pause, and then flash three times.
4. Error Codes
The Error Code designations indicating malfunction, or no malfunction, are listed below:
Code
No Error found
12
Lamp cover is open.
32
Lamp turns Off while the TV is playing.
34
Lamp ballast fan failed.
36
Red/Green LCD-PBS fan failed.
37
Lamp temperature abnormally high.
38
LCD Intake temperature abnormally high.
39
Standby Short Detected.
41
Exhaust (lamp) fan failed.
42
Check for disconnected DVI cable between PWB-DM and Engine.
44
BLUE LCD fan failed.
45
LCD Intake Temperature sensor not detected.
46
Engine power supply short is detected. (P-ON short)
48
Lamp did not turn on at P-ON sequence
66
Lamp Troubleshooting
Use the above Error Code Table, and the Lamp Control Block diagram and Troubleshooting flow chart on the following pages
to determine the cause of a lamp problem.
MODEL: WD-52531 / WD-62531 / WD-62530
ABNORMAL LED INDICATIONS
Lamp Indicator
Yellow
Off
Off
Yellow
Off
Blinking yellow
Off
Red
Off
Red.
Off
ERROR CODES
Temperature high – room temperature too hot.
Temperature sensor is disconnected.
Lamp usage warning (over 5000 hours)
Lamp cover is open.
Lamp fails to turn on
Fan Stop
Circuit failure (short)
DVI cable between DM and Engine disconnected
Ballast problem detected by ballast UART (temperature,
short circuit, did not ignite, low voltage)
Description