Pin No.
Pin Name
195
SI0
196
SO0
197
SCK0
198
XGUM_ON
199
BEEP
200
XOPT_CTL
201
LAM_REQCHK
202
LAM_SPREQ
REC_LED
203
/ACCESS_LED
204
MDVCC_CTL
205
VBUS_VB_CTL
206
LAM_NAME
207
PE7
208
PF0
209
PF1/S0DO
210
PF2/S1DO
211
PF3/RTG3
XMUTE
212
/MUTE
213
SI1
214
SO1
215
SCK1
216
SLD_MON
217
AOUT_SEL
218
YUZU_SLEEP
219
FFCLR
220
CHGI_CTL1
221
CHGI_CTL2
222
CHGI_CTL3
223
SLBUSY
224
XTEST
225
XRF_RST
226
VREC_SEL
227
XHOLD_SW
228
T_MARK_SW
229
XRST2_DET
230
CHGI_SEL
231
RECP_MON
232
SPDL_MON
233
XCS_PWR_IC
234
RXD
235
TXD
236
XCS_LCD
CC_CTL
237
/VI_CTL
I/O
I
Serial data input from the EEPROM
O
Serial data output to the EEPROM
O
Serial clock output to the EEPROM
I
Rechargeable battery detection signal terminal Not used
O
Beep sound control signal output to the headphone amplifier
O
Power supply ON/OFF control signal output for the DIN PD drive Not used
I
LAM power check terminal Not used
O
LAM force stop request signal output Not used
O
REC or Access LED drive signal output terminal Not used
O
Power supply control signal output for the OP modulation
O
USB power supply control signal output terminal
O
LAM name data request signal output terminal Not used
Not used
Not used
O
Connect to the optical pick-up block
O
Connect to the optical pick-up block
O
Connect to the headphone amplifier
O
Muting on/off control signal output terminal
I
Serial data input from the LCD module
O
Serial data output to the LCD module
I/O
Serial data transfer clock signal input/output terminal with the LCD module
I
Sled servo monitoring terminal
O
Headphone/line output switching terminal Not used
O
Chip enable output to the power control IC
O
Input latch output for the start switching to the power control Not used
Charge current limiter control signal output at the time of DC adaptor use
O
"L": charge Not used
O
Charge current control signal output terminal "L": low current charge Not used
O
Charge current control signal output terminal "L": low current charge Not used
I
Receive signal monitoring terminal for sled command
I
Terminal for the test mode setting (normally open) "L": test mode
O
Reset signal output to the RF amplifier
O
VREC start-up timing control signal output terminal
I
HOLD switch detection input terminal
I
Track mark switch input terminal Not used
I
Reset signal input from the power control IC
O
Charge/discharge control signal output for current sense amplifier Not used
I
Laser power changeover signal monitoring terminal
I
Spindle servo monitoring terminal
O
Chip select signal output to the power control IC
I
Not used
O
Not used
O
Chip select signal output to the LCD module
O
Constant current circuit control signal output terminal Not used
Description