Notes Wall Mounted Terminations: SIDE VENT
All dimension lengths for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs must fall within the limits set by the venting graphs,
see Figure 13.
Fireplace must be converted to Rear Vent configuration prior to
running vent, see Figure 8 and 8a.
The Venting Graph
Measure the vertical height from the fireplace hearth to the centre of the
termination and the horizontal run from the fireplace flue collar to the wall
flange of the termination. Plot on the Venting Graph Figure 13 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the horizontal
run to the wall flange of the vent termination is 138", this would be
an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 48" and the horizontal
run to the wall flange of the vent termination is 96", this would be
would NOT be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 72" and
the horizontal run to the wall flange of the vent termination is 120",
this would NOT be an acceptable installation.
Acceptable vent run
within non-shaded area.
B
42"
42"
26 3/4"
12"
Figure 13. Side Vent Venting Graph for wall mounted terminations.
WARNING
An inspection of the explosion relief flappers and door MUST be made prior to
lighting the fireplace. A faulty seal on the door gasket and/or explosion ports will
result in products of combustion leaking into the living space and may result in
carbon monoxide poisoning.
Page 14
Installation
A
C
Unacceptable vent run
within shaded area.
If your installation does not fall within
the venting parameters, contact a
local Montigo dealer for Power
Venting options.
NOTE:
12" MAX. horizontal
run with no vertical lift.
Hearth
Figure 13a. Straight run, Side Vented, wall mounted termination for
L38DF-ST*, Figure 13.
Flex or Rigid
Section
Figure 13b. Side Vented, wall mounted Multi-elbow termination
installation. Installation for L38DF*-ST must have a minimum
vertical rise of 42".The vent run must comply with the Venting
Graph for Rear vent, wall mounted terminations, Figure 13.
PXT Extension
RHS101 Heat
Shield
Termination
12" MAX.
26 3/4"
Exterior
Wall
30" Max.
15 1/4"
Min.
42" Min.
12"
Max.
26 3/4"
Hearth
XG0810 - 070714