Section 4: Wiring; Installing On/Off Wall Switch - Montigo L52DF-ST Installation And Maintenance Manual

L-series indoor gas fireplace
Table of Contents

Advertisement

Section 4: Wiring

ON / OFF
ON/OFF
Battery
Holder
4 x 1.5V
AA Type
Red
Black
BATTERY
120 Vac INPUT
7 Vdc STABILIZED
DC SUPPLY
SUPPLY OUTPUT
Installing the remote On/Off Wall Switch
The L52DFST* gas valve may be connected to a wall switch. Do
NOT connect any external power to the remote switch. The valve will
generate its own power on a millivolt circuit or will draw its power from
an AC Connection inside the fireplace, depending on the model of the
unit. Use only low voltage wire, and DO NOT connect any external
power to the remote switch.
Refer to Figure 12 or 13 for wiring requirements.
NOTE: The switch location must not exceed 30' from the fireplace.
XG0811 -100511.1
Installation
(CPI / IPI MODE
Not Used)
IPI/CPI
GROUND
Figure 12. Wiring Diagram for the SIT Proflame Electronic Ignition
'Hi-Lo' Adjustment Knob
Manifold Pressure
Test Connection
Inlet Pressure
Gas Control Knob (Shown in "Pilot" position)
Figure 13. Wiring Diagram for SIT Nova 820 gas and pilot.
Green
Orange
880 Valve
VALVE
Chassis
connection
Pilot Adjustment Screw
NOTE:
If any of the original wire supplied with the appliance is
replaced, it must be replaced with the same type, or its
equivalent.
L52DF-ST* Indoor Gas Fireplace
Models Included
L52DF-STN-F
L52DF-STL-F
DFC
Power
Models Included
Generator
L52DF-STN
L52DF-STL
Wall Switch