Lockout And Reset Sections; Installer Lockout Enable; Installer Lockout Disable; Factory Default - DSC PC2525 Installation Manual

Version 1.1
Hide thumbs Also See for PC2525:
Table of Contents

Advertisement

LOCKOUT AND RESET SECTIONS

[90] Installer Lockout Enable

When this feature is enabled, performing a hardware or software reset to restore the system's factory
programming will not reset the Installer's Code or the Downloading Access Code.
To enable this feature, enter Section [90]. After entering Section [90], enter [Installer's Code][90] to confirm
activation of this feature. If the Installer's Code and the Section number are not entered correctly, the keypad will
sound a single long tone to indicate the error and the feature will not be enabled.
A panel that has this feature enabled will provide an audible indication upon power-up by clicking the telephone
line relay 10 times. Ensure that the new Installer's Code has been entered correctly before enabling this feature
as there is no way of re-entering the Programming Mode without the new Installer's Code.

[91] Installer Lockout Disable

Entering Section [91] while in the installer's Programming Mode will disable the Installer Lockout feature
described in Section [90].
To enable this feature, enter Section [91]. After entering Section [91], enter [Installer's Code][91] to confirm
activation of this feature. If the Installer's Code and the Section number are not entered correctly, the keypad will
sound a single long tone to indicate the error and the feature will not be enabled.
NOTE: Panels returned to DSC with the Installer Lockout feature enabled and no other apparent problems will be
subject to an additional service charge.

[99] Factory Default

Enter this section to reset the system's programming to the factory default settings.
To enable this feature, enter Section [99]. After entering Section [99], enter [Installer's Code][99] to confirm
activation of this feature. If the Installer's Code and the Section number are not entered correctly, the keypad will
sound a single long tone to indicate the error and the feature will not be enabled.

Hardware Reset of System Programming

If the Installer's Code is lost or forgotten, the system's memory must be restored to the factory default settings
before programming may be performed. Note that if the Installer Lockout feature has been enabled, the
Hardware Reset will not restore the default Installer's Code.
To restore the factory default programming:
1
Remove power from the system by disconnecting the AC and battery
2
Remove any connections to the Zone 1 and PGM terminals
3
Connect the Zone 1 and PGM terminals together
4
With the Zone 1 and PGM terminals connected, apply AC power to the system
5
Wait for 20 seconds after applying power and then remove the connection between the Zone 1 and PGM terminals
6
The system's factory default programming has now been restored. Note that if the Installer's Lockout feature had
been enabled, the Installer's Code and the Downloading Access Code will not be reset to the default settings.