Installation Guide At The Seaside - LG Air Conditioner Installation Manual

Wall mounted type wall mounted mini-split system single zone
Hide thumbs Also See for Air Conditioner:
Table of Contents

Advertisement

Installation

Installation guide at the seaside

1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced.
2. Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion
on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunc-
tion or inefficient performance.
3. If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind. Otherwise it
needs additional anticorrosion treatment on the heat exchanger.
Selecting the location(Outdoor Unit)
1) If the outdoor unit is to be installed close to the seaside, then direct exposure to the sea wind should be avoided.
Install the outdoor unit on the opposite side of the sea wind direction.
Sea wind
2) In case of installing the outdoor unit on the sea side, setup a windbreak to prevent sea wind.
Windbreak
Sea wind
3) Select a well-drained place.
1. If you can't meet above guide line in the seaside installation, please contact LG Electronics for the additional anticorrosion treatment.
2. Periodic ( more than once/year ) cleaning of the dust or salt particles stuck on the heat exchanger by using water
28 Air Conditioner
Sea wind
• It should be strong enough like concrete to prevent the
sea wind from the sea.
• The height and width should be more than 150%
of the outdoor unit.
• Keep more than 70 cm of space between
outdoor unit and the windbreak for easy air flow.