Forming The Piping - LG Air Conditioner Installation Manual

Wall mounted type wall mounted mini-split system single zone
Hide thumbs Also See for Air Conditioner:
Table of Contents

Advertisement

Forming the Piping

In cases where the outdoor unit is
installed below the indoor unit
perform the following.
1. Tape the piping, drain hose and connecting
cable from down to up.
2. Secure the tapped piping along the exterior
wall using saddle or equivalent.
In cases where the Outdoor unit is
installed above the Indoor unit
perform the following.
1. Tape the piping and connecting cable from
down to up.
2. Secure the taped piping along the exterior
wall. Form a trap to prevent water entering
the room.
3. Fix the piping onto the wall using saddle or
equivalent.
Seal small openings
around pipings with a
gum type sealant.
Saddle
Trap is required to prevent water
from entering into electrical parts.
Seal a small opening
around the pipings
with gum type sealant.
Trap
Trap