MONITOR
MAIN MONITOR : This connector is used for the Main monitor display, A number of different
3
CALL MONITOR : This connector is used for the Call(secondary) monitor. This monitor can only
4
MAIN
MONITOR
When the machine is in Menu, Search or Copy mode, the internal Video is switched to Monitor Out, so that the user
can view full screen OSD. In other modes, the Video from multiplexer main monitor will be loop-through to the Monitor
Out.
VIDEO IN /Output
VIDEO IN (1~4): The BNC connectors of video input enables the system to receive the signals from
5
each camera through the 75 ohm coaxial cables.
VIDEO OUT(1~4) : Connect the other devices with four cameras to the other devices.
Alarm Input/ Output
Alarm Input
6
ALM-INPUT :
Normal Open or Normal Close type alarm sensor input.
The Alarm Input can be selected as Normal Open or Normal Close input in the setup
menu. When an alarm occurs, alarm recording will automatically start.
ALM-OUTPUT : Normal Close Alarm output. In normal condition, this terminal is
display modes may be selected for viewing.
display full screen.
SW3
INTERNAL
VIDEO
shorted to the terminal of ALM-COM. In alarm status, it is open
between ALM-NC and ALM-COM terminals.
( Internal circuit )