Verify Pol Hardware Limits; Single Speed Pol Drive Hardware Limits; Figure 15: Verify Hardware Limits Screen - Andrew OMACS3000 User Manual

Andrew antenna control system user guide
Table of Contents

Advertisement

11-APR-06
up or down. All four directions must be jogged to their limit and all four check boxes must be displayed
before the operator can go on to the next step in the Initialization Wizard.

Verify Pol Hardware Limits

The antenna observer used for the AZ and EL Hardware Limits verification is necessary for the Pol hardware
limits verification as well. The observer is needed to request emergency stop from the operator if any wires
or wire harnesses become entangled as the antenna moves or the antenna moves beyond its physical limits.
The observer must be in position to stop the hardware
from moving into obstructions, twisting wires, or moving
beyond physical limits.

Single Speed Pol Drive Hardware Limits

If a single speed (1:1 ratio) pol drive is installed, the operator moves to the counter-clockwise limit as
directed by the screen. (See
operator will know that the limit is reached when that direction checkbox is checked. The operator should
also notice that the resolver counts (as displayed by the position status line) discontinue counting down.
When the pol counter-clockwise limit is reached and the operator verifies that the hardware limit is ok by
pressing the completed button, the system software will adjust the pol offset so that the counter-clockwise
limit reads 2.0 degrees.

Figure 15: Verify Hardware Limits Screen

WARNING
Figure 16
) The operator will jog until that axis reaches the physical limit. The
23 of 51
Rev E
OMACS3000
System Screens

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs3000

Table of Contents