TROUBLESHOOTING
SIGNATURE COMMAND SYSTEM
OPERATION 
Install batteries and/or 
plug in the AC board 
Flip the master switch 
(rocker switch) to the  
ON position 
Press the ON button on 
the Command Center 
62D4037
FAULT 
No beep in about 
8 seconds 
No beep
or
no sound from the
valve indicating pilot
solenoid open
No sparking on  
the pilot 
Sparking doesn't  
continue 
Pilot doesn't light 
Main burner doesn't  
light 
FP1911 
troubleshoot sc 
8/08 
BBV, SBV Series Natural Vent Gas Fireplaces
DIAGNOSIS 
Using 
Battery polarity wrong? 
battery? 
Make sure 
Command 
Battery voltage low? 
Center and 
the control 
board are 
connected by 
a 2 feet or 15 
AC plug is plugged to 
feet cable 
AC mains? 
The 5-pin connector on 
the AC board broken or 
bent? 
LED on the Command 
Center does not show 
solid green? 
Check NG/LP 
Check valve 
conversion cap 
connections 
and control  
board  
connections 
Check 
Check pilot 
grounding 
connections 
The Control Board is having interference from the 
surrounding metal (Ground) 
Check gas supply 
Go through  C 
The sensor on the pilot  
Go through  
is not in the flame  
(pilot flame too small)? 
ACTION 
Re-install batteries 
Change batteries 
Plug the AC plug to  
AC mains 
Repair or replace the  
AC Board 
Replace the AC Board 
Check power 
Replace the Control  
supply (go 
Board or  
through       ) 
Command Center 
Sparking is happening 
Go through 
elsewhere (under the 
pilot), re-install/replace 
the pilot 
Re-install the Control  
Board, move it around 
or change the 
Control Board 
Sparking is not in the  
path of gas flow, adjust  
sparker position or  
replace the pilot 
Adjust sensor position  
or replace the pilot 