ELECTRICAL INSTALLATION

REMOTE WALL MOUNTED SWITCH

A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach
the wall switch in a junction box at the desired location on the wall. Figure 18. Do not extend beyond
the wall switch wire length provided.
NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length
of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with
local codes.
PILOT
HI
TH
TP
TH/TP
Figure 18 -
Wall Switch Wiring Diagram
62D4037
BBV, SBV Series Natural Vent Gas Fireplaces
Do not connect wall switch to AC
(110 V) circuit.
SPILL
SWITCH
ON
RS
OFF
OPTIONAL REMOTE
WALL SWITCH
ON
OFF
OPTIONAL REMOTE
WALL SWITCH
ON
OFF