Dimplex EVX050 Installation And Operating Instructions

Electronic panel convector heater

Advertisement

Electronic Panel Convector Heater
:
Models
EVX050 / EVX075 / EVX100 / EVX125 / EVX150 / EVX200
EVS050 / EVS075 / EVS100 / EVS150
Dimensions and Specification
Model
Loading
Length (A)
(kW)
(mm)
EVX050
0.5
440
EVX075
0.75
440
EVX100
1.0
440
EVX125
1.25
440
EVX150
1.5
440
EVX200
2.0
440
EVS050
0.5
580
EVS075
0.75
820
EVS100
1.0
1060
EVS150
1.5
1300
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
IMPORTANT SAFETY ADVICE
When using electrical appliances, basic precautions should always be
followed to reduce the risk of fire, electrical shock, and injury to
persons, including the following:
WARNING THE SURFACES OF THIS HEATER CAN BE HOT
Momentary contact with any part of the heater should not cause injury.
However, aged or infirm persons or young children should not be left
unsupervised in the vicinity of the heater unless a suitable guard is
fitted
IMPORTANT – If this heater is installed in a room containing a bath or
shower, it should be so installed that switches and other controls
cannot be touched by a person using a bath or shower – to comply
with this requirement see 'Lock the Control Cover' section on page 2.
If you use this heater in conjunction with an external thermal control, a
programme controller, a timer or any other device which switches the
heat on automatically, observe all safety warnings AT ALL TIMES since
a fire risk exists when the heater is accidentally covered or displaced
The installation of this product should be carried out by an electrician
or competent person and be in strict accordance with the current IEE
Wiring Regulations and relevant Building Regulations
This heater must not be mounted within 150mm of curtains and other
combustible materials or 100mm from a shelf or overhang
NEVER cover or obstruct in any way the heat outlet slots at the top of
the heater or the air inlet slots at the base of the heater
DO NOT cover the heater – Do not place material or garments on the
heater or obstruct the air circulation around the heater
Before connecting the heater check that the supply voltage is the same
as that stated on the heater
The heater must be installed in accordance with these instructions
The heater must be mounted using the wall bracket supplied. The
heater should only be operated in the upright position
The heater should be positioned in accordance to the clearances
stated in these instructions
DO NOT locate this heater immediately beneath a fixed socket outlet
Electrical
The wires in the mains lead are coloured in accordance with the following code:
GREEN & YELLOW
EARTH
BLUE
NEUTRAL
BROWN
LIVE
BLACK
PILOT WIRE
(See also 'Pilot Wire Connection')
The heater is fitted with a length of flexible cable for connection to the fixed wiring of
the premises through a suitable connection box positioned adjacent to the heater.
The supply circuit to each heater must incorporate a double pole isolating switch having
a contact separation of at least 3mm
Pilot Wire Connection
The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex
programmers. If, however a programmer is not being used, the pilot wire should be
isolated in accordance with the current IEE Wiring Regulations.
IMPORTANT - Do NOT connect the BLACK pilot wire to earth
Care should be taken with the installation of the pilot wire(s) as when switching to
background (set back) they become energised at 240V although only at a current of 1mA.
In every case a suitable means of isolation must be provided for the pilot wire and marked
to indicate that two sources of supply may be present at the heater.
Where pilot wires are installed separately from the heater final sub-circuit they should be
protected, double insulated and carry their own integral earth continuity conductor.
Height
Depth
X
Y
(mm)
(mm)
(mm)
(mm)
340
107
156
90
340
107
156
90
420
107
236
90
500
107
178
107
580
107
248
117
740
107
405
120
220
107
186
149
220
107
426
149
220
107
666
149
220
107
906
149

Installation and Operating Instructions

Z
Weight
(mm)
(kg)
94
3.5
94
3.5
94
4.2
215
4.8
215
5.4
215
6.6
245
3.4
245
4.6
245
5.7
245
6.9
General
The compact EVX and low profile EVS are designed to provide rapid
heat warm up in both domestic and commercial applications.
Wall Mounting / Installation
The heater should be positioned observing the minimum clearances
stated around the heater.
(see also 'Electrical' section)
EVX Range
The wall bracket supplied with the heater must be used
1.
Remove wall mounting bracket from back of heater by de pressing
the two spring latches at the top of the heater (see Fig.1)
2.
Fix wall bracket securely to wall via the three or four holes in the
bracket with the appropriate fixings for the wall type (see Fig.2)
3.
Present heater to wall bracket and engage the two lower slots first.
Then line up and push in the top two slots until the spring latches
click in to place
Model
A (Width)
EVX050
EVX075
EVX100
EVX125
EVX150
EVX200
EVS Range
(Fig.3)
1.
Mark the fixing positions for the top two screws on the wall
in accordance with the dimensions shown in the diagram
below, ensuring the two top fixing points are level
2.
Fix the two screws to the wall and hang the heater through
the top two key hole slots
3.
Finally, secure the heater with two more screws at the base
IP24
Issue 5 November 2004
Fig.1
B (Bracket Width)
340
156
340
156
420
236
500
178
580
248
740
405
Fig.3
Fig.2

Advertisement

loading

Summary of Contents for Dimplex EVX050

  • Page 1: Installation And Operating Instructions

    Finally, secure the heater with two more screws at the base Pilot Wire Connection The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex programmers. If, however a programmer is not being used, the pilot wire should be isolated in accordance with the current IEE Wiring Regulations.
  • Page 2: Mode Selection Dial

    Note: If the programme function is selected but no programming device is being used, the heater will function in comfort mode The following Dimplex programmers are available Fig.4 Pilot Wire Wall Mounted Controller (2 Zone) – Part no. RX010006 MBS Wall Mounted Programmer (2 Zone) –...

This manual is also suitable for: