Roubleshooting Gas Control (Honeywell) - Vermont Castings LHERDV20 Owners Installation And Operating Manual

Vermont castings direct vent insert - homeowner's installation and operating manual
Table of Contents

Advertisement

Troubleshooting the Gas Control System
Gas Supply On
Pilot Lights With
Piezo Ignitor
Pilot Stays Lit
Pilot Lights Main
Burner
System OK.
10004894
Honeywell Millivolt Valve
START
NO
YES
NO
YES
NO
YES
NO
YES
FP396
NVC-standing pilot troubleshooting
11/22/96
CHECK
Supply Line Hooked Up
Shutoff Valve Open
Lockout Has Engaged. Wait
60 Seconds And Try Again.
For Spark At Electrode While
Depressing Piezo — 1/8" Gap To
Pilot Hood Needed.
All Wiring Connections
Replace Piezo Ignitor
For Air In The Lines
Thermopile Needs A Minimum
325mv. Adjust Pilot Flame Height.
All Wiring Connections.
Replace Thermopile
Thermocouple Needs A Minimum
of 14mv.
Defective Valve. Turn To Pilot,
Meter Should Read Greater Than
100 Mv. If Not, Replace.
Valve Is Turned On
On/off Switch Is Not Turned On.
Watch For Grounded Wires!
Thermopile Needs A Minimum
325mv.
Plugged Burner Orifice.
LHEDV Series Direct Vent Insert
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lherdv30Lhecdv30Lhecdv20

Table of Contents