7-4. How to Test Run the Air Conditioner

After turning on power to the air conditioner, use the remote
controller and follow the steps below to conduct the test run.
(1) Set the remote controller in Test Run mode. (Fig. 8a)
a) Press and hold the QUIET button.
b) Then press and hold the 1HR TIMER button.
c) At the same time, press the ACL (reset) button once.
Use a pointed object such as the tip of a pen to press
the ACL button.
• After a few seconds, "
the remote controller display area. (Fig. 8b)
d) Release the 1HR TIMER button.
e) Release the QUIET button.
(2) Start Cooling mode test run by pressing the ON/OFF
operation button of the remote controller. (Fig. 8a)
• This starts the fan producing uncooled forced air with
the 3 indicator lamps (OPERATION lamp, TIMER lamp
and LED CLEAN lamp) on the main unit blinking.
(Fig. 8c)
• After 3 minutes, the system shifts into cooling
operation, and cool air will start to be felt. Cool mode
test run is unaffected by the room temperature.
(3) Press the ON/OFF operation button of the remote
controller again to stop the test run. (Fig. 8a)
(4) Finally press the ACL (reset) button of the remote
controller to release it from Test Run mode to return to
normal mode. (Fig. 8a)
• "
" and "oP-1" will disappear from the remote
controller display area.
IMPORTANT
After the test run is completed, be sure to press the ACL
(reset) button to return to normal mode. The air conditioner
will not operate correctly if this is not done.
" appears and "oP-1" blinks in
QUIET
button
LED CLEAN lamp
27
ON/OFF
operation
button
1HR.
TIMER
button
ACL
(Reset)
button
Fig. 8a
Fig. 8b
TIMER lamp
OPERATION lamp
Fig. 8c