Gem-Rp2Ase2/Gem-K2As Keypad Easy Program Menu; Total Number Of Zones In Area 1; Total Number Of Zones In Area 2; Fire Zones In Area 1 - Gemini GEM-P9600 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEM-P9600:
Table of Contents

Advertisement

!
Page 6

GEM-RP2ASe2/GEM-K2AS Keypad Easy Program Menu

Enter the Dealer Security Code (default = 456789) for a new panel or enter your custom Dealer Program Code if
GEMINI
SYSTEM ARMED
programmed. Press the PRIOR/NO button repeatedly until "TURNON/PROG" is displayed. NOTE: If you pass "TURNON/
ENT A1
ENT A1
01/01/97 12:00AM
PROG", you can scroll back by pressing
NEXT/YES
A
1 2
3
E
D
PRIOR/NO
B
4
5 6
F
each of the following steps, press
AREA
C
7 8 9 0
G
COMPUTERIZED SECURITY SYSTEM
R
PRIOR/NO button to go backwards,
Total Number of Zones in Area 1 (New Program Only)
Ent A1
#ZnX X
group of 4. For example, if you enter 18, it will automatically convert this to 20 zones. Press
(Direct Entry)
NEXT/YES button to proceed.
Total Number of Zones in Area 2 (New Program Only)
Ent A2
#ZnX X
group of 4. For example, if you enter 18, it will automatically convert this to 20 zones. Press
(Direct Entry)
NEXT/YES button to proceed.
Fire Zones in Area 1 (New Program Only)
Ent Fr
Zn#X X
zone(s). Press the NEXT/YES button to proceed.
(Direct Entry)
2-Wire Fire Zones in Area 1 (New Program Only)
Ent2WF
Zn#X X
NOTE: Only zones which have been designated as Fire Zones can be programmed as 2 Wire Fire zones. JP3 must
be set to "2-WF" position for 2-wire fire. (refer to Installation Instructions).
(Direct Entry)
Local or Central Station Reporting System (New Program Only)
Report
Press the NEXT/YES button for all zones to report; press the PRIOR/NO button for local system.
all Zn
Y/N
(Press YES or NO)
Exit/Entry Zones in Area 1 (New Program Only)
EntEE1
Zn#X X
NOTE: Exit/Entry Entry time of 30 seconds will automatically be programmed.
(Direct Entry)
Interior Zones in Area 1 (New Program Only)
EntFol
Zn#XX
(Direct Entry)
X
GEM-P9600 Programming Instructions
B
R
U
to save and
Enter the total number of zones to be programmed for Area 1.
Valid entries are from 01 to 96. Directly enter the total number of zones, including leading zeros.
The system is based on groups of 4 zones each (after the first 8 zones), and will automatically round up to the next
Enter the total number of zones to be programmed for Area 2.
Valid entries are from 01 to 96. Directly enter the total number of zones, including leading zeros.
The system is based on groups of 4 zones each (after the first 8 zones), and will automatically round up to the next
Enter the zone number of any Fire Zones (including 2-wire, 4-wire or wireless).
Valid entries are from 01 to 96.
Directly enter each zone number, including leading zeros, and press
Enter the zone number of any Fire Zone (from previous question) to be used with 2-wire smoke detectors.
Valid entries are 07 and 08. Directly enter each zone number, including leading zeros.
U
Press
to save, and repeat for any additional zone(s); press NEXT to proceed.
Enter the zone numbers of zones to be used as Exit/Entry zones.
Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.
U
Press
to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
Enter the zone numbers to be used as Interior Zones.
Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s).
Press the NEXT/YES button to proceed.
All Interior zones will also be automatically programmed as "Exit/Entry Follower" and as "Power Up Delay" zones.
. Press the NEXT/YES button to enter the Dealer Program Mode. In
to jump to the next screen, the NEXT/YES button to go forwards, the
twice to exit at any time.
C
WI 1185 6/03
U
to save. Press the
U
to save. Press the
U
to save, and then repeat for any additional
L
NAPCO Security Systems