4) Heating operation
No
Fan motor operate in rated
fan speed
No (not rated
Operate in set fan
speed
Heating operation
Swing
Swing action
Defrosting
No
Rated
According to temperature
sensor to adjust state and
valve open degree
Overload protection
No
Auto
fan
Yes
According to room temp and set
temp to determine fan speed
Send
indoor
Operation
State
outdo
or unit
A
-48-
No
Swing flap in set fan
speed position
Yes
On
Yes
expansion valve steady
Off
expansion valve totally
open
Yes
unit
to
side:
wind
off,
side:
Electronic
If stop unit
protection
Yes
Electronic
expansion
valve close
Protect
according
temperature
difference
section value
to