Integrated Circuit Diagrams - JBL PowerBass PB12 Service Manual

Powerbass series
Hide thumbs Also See for PowerBass PB12:
Table of Contents

Advertisement

PB12
+6V 15
16
17
V+
18
O/P 19
20
21
V-
22
+15V
23
SD
24
FR
25
I/P
26
GND
27
-15V
28
U1,U2 (LM324, TLO64))

Integrated Circuit Diagrams

S53AMI/S64AMI - Power Amp module SAFETY PART
1
+6V
2
3
V+
4
O/P
5
6
7
V-
8
9
+15V
10
SD
11
FR
12
I/P
13
GND
14
-15V
N-Chan JFET
Q1 2N5457
D
S
G
NOTE: THE FOLLOWING PROCEDURES MUST BE
FOLLOWED WHEN INSTALLING NEW S53AMI/S64AMI
AMP MODULES:
FAILURE TO FOLLOW ONE OR MORE OF THESE STEPS
MAY RESULT IN THE INSTANT DESTRUCTION OF THE
MODULE WHEN POWERED UP.
1. Align white indent marker on Amp Module with indent
marker on main PCB; alternately observe position of label
on top of the module; incorrectly replacing the Module
180° in the PCB slot will result in its destruction.
2. All AC powered test instruments (meters, oscilloscopes,
etc.) must have a floating ground, i.e., be connected to an
isolation transformer.
3. Align and position the Amp Module before soldering.
4. Attach the amp Module with the mounting screws before
soldering or powering up.
5. Use only rosin-core or non-acid core solder; thoroughly
de-flux the surfaces after soldering.
If the new S53AMI/S64AMI Amp Module has larger mounting
hole(s) in the case, and the stock screws no longer will fit,
and screws of the proper type cannot be obtained locally
order:
(2) part# 60301S (screws)
(2) part# 60301N (nuts)
Q10,Q11 (MPSA56)
3 Collector
2
Base
1 Emitter
1
2
3
19
Q12 (2N4401)
3 Collector
2
Base
1 Emitter
1
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents