Fujitsu ABYF24LAT Operating Manual

Floor console/under ceiling dual type
Hide thumbs Also See for ABYF24LAT:

Advertisement

AIR CONDITIONER

OPERATING MANUAL

FLOOR CONSOLE/
BEDIENUNGSANLEITUNG
MODE D'EMPLOI
UNDER CEILING
MANUAL DE FUNCIONAMIENTO
DUAL TYPE
MANUALE DI ISTRUZIONI
ΕΓ ΕΙΡΙ∆Ι
ΛΕΙΤ ΥΡΓΙΑΣ
MANUAL DE INSTRUÇÕES
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
KULLANMA K‹TABI
KEEP THIS MANUAL FOR FUTURE REFERENCE
DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN
CONSERVEZ CE MODE D'EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT
GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO
CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO
ΚΡΑΤΗΣΤΕ Τ ΕΓ ΕΙΡΙ∆Ι
ΓΙΑ ΜΕΛΛ ΝΤΙΚΗ ΑΝΑΦ ΡΑ
GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR
СОХРАНИТЕ НАСТОЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК
BU KILAVUZU, DAHA SONRA BAfiVURMAK ÜZERE SAKLAYIN
P/N9374379262-03
9374379262-03_OM_cover1.p65
1
2/4/10, 3:05 PM

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ABYF24LAT

  • Page 1: Air Conditioner

    AIR CONDITIONER OPERATING MANUAL FLOOR CONSOLE/ BEDIENUNGSANLEITUNG MODE D’EMPLOI UNDER CEILING MANUAL DE FUNCIONAMIENTO DUAL TYPE MANUALE DI ISTRUZIONI ΕΓ ΕΙΡΙ∆Ι ΛΕΙΤ ΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ KULLANMA K‹TABI KEEP THIS MANUAL FOR FUTURE REFERENCE DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN CONSERVEZ CE MODE D’EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ........1 ADJUSTING THE DIRECTION OF FEATURES AND FUNCTIONS ......2 AIR CIRCULATION ..........9 NAME OF PARTS ........... 2 SWING OPERATION ..........10 PREPARATION ............4 ECONOMY OPERATION ........10 OPERATION ............5 CLEANING AND CARE ........11 TIMER OPERATION ..........
  • Page 3: Features And Functions

    FEATURES AND FUNCTIONS AUTOMATIC OPERATION WIRELESS REMOTE CONTROLLER G COOLING MODEL The WIRELESS REMOTE CONTROLLER allows convenient control of air conditioner operation. Merely press the START/STOP button, and the unit will begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting OMNI-DIRECTIONAL AIR FLOW and the actual temperature of the room.
  • Page 4 NAME OF PARTS Remote controller Display panel Display Display To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in ac- tual operation, however, the display will only show those indicators appropriate to the current operation. F Signal Transmitter 1 MODE button G Temperature SET Display...
  • Page 5: Preparation

    PREPARATION Load Batteries (R03/LR03 × × × × × 2) CAUTION! G Take care to prevent infants from acciden- tally swallowing batteries. Press and slide the battery compartment lid on the re- G When not using the Remote Controller for verse side to open it.
  • Page 6: Operation

    OPERATION To Select Mode Operation Press the START/STOP button. The indoor unit’s OPERATION Indicator Lamp (green) will light. The air conditioner will start operating. Press the MODE button to select the desired mode. Each time the button is pressed, the mode will change in the following order.
  • Page 7 To Stop Operation Press the START/STOP button. The OPERATION Indicator Lamp (green) will go out. About AUTO CHANGEOVER Operation G When AUTO CHANGEOVER operation first selected, the fan will ope- AUTO: rate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode.
  • Page 8: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the Remote Controller is set to the correct current time ( P. 4). If the indoor unit is connected to a Wired Remote Controller, the Wireless Remote Controller cannot be used to set the timer. To Use the ON timer or OFF timer Press the START/STOP button To Cancel the Timer...
  • Page 9: Sleep Timer Operation

    SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. If the indoor unit is connected to a Wired Remote Controller, the Wireless Remote Controller cannot be used to set the sleep timer.
  • Page 10: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). G Adjust the up, down, left and right AIR directions with the AIR DIRECTION buttons on the Remote Controller. G Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airflow-direction louvers have stopped moving.
  • Page 11: Swing Operation

    SWING OPERATION Begin air conditioner operation before performing this procedure. To select SWING Operation Press the SWING button. Each time the SWING button is pressed, the swing operation will change in the following order. Up/down swing operation Left/right swing operation Swing operation stops Up/down/left/right swing operation To stop SWING Operation...
  • Page 12: Cleaning And Care

    CLEANING AND CARE G Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply cable. CAUTION! G Be sure the intake grille is installed securely. G When removing and replacing the air filters, be sure not to touch the heat exchanger, as per- sonal injury may result.
  • Page 13: Selecting The Remote Controller Signal Code

    SELECTING THE REMOTE CONTROLLER SIGNAL CODE When two or more air conditioners are installed in a room and the Remote Controller is operating an air conditioner other than the one you wish to set, change the signal code of the Remote Controller to operate only the air conditioner you wish to set (four selections possible).
  • Page 14 TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Symptom Problem See page G Some smell may be emitted from the indoor unit. This smell is NORMAL Smells: FUNCTION the result of room smells (furniture, tobacco, etc.) which have —...
  • Page 15: Operating Tips

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). *Heating Performance *Microcomputer-controlled Automatic Defrosting G This air conditioner operates on the heat-pump principle, G When using the Heating mode under conditions of low absorbing heat from outdoor air and transferring that heat outdoor temperature and high humidity, frost may form indoors.
  • Page 16: Auto Restart

    OPERATING TIPS About Mode Operation Heating: G Use to warm your room. During Heating mode: G When Heating mode is selected, the air conditioner will operate at very Set the thermostat to a temperature set- low fan speed for about 3 to 5 minutes, after which it will switch to the ting that is higher than the current room temperature.
  • Page 17 Multi-type Air conditioner This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output.

Table of Contents