Mitsubishi Electric PUHZ-P200YHA Service Manual page 54

Split-type, heat pump air conditioners outdoor unit
Hide thumbs Also See for PUHZ-P200YHA:
Table of Contents

Advertisement

Outdoor noise filter circuit board
PUHZ-P200YHA
PUHZ-P250YHA
GD1
Connect to the earth
CNAC1, CNAC2
AC220/230/240V
(Connect to the
outdoor controller
circuit board (CNAC))
GD2
Connect to the earth
CNDC
(Connect to the
outdoor controller
circuit board
(CNDC))
CNL
Connect to the ACL4
LI1, LI2, LI3, NI
POWER SUPPLY
LI1-LI2/LI-LI3/LI3-LI1 : AC380/400/415V input
LI1-NI/LI2-NI/LI3-NI : AC220/230/240V input
(Connect to the terminal block (TB1))
LO1, LO2, LO3
POWER SUPPLY
LO1-LO2/LO2-LO3/LO3-LO1 : AC380/400/415V OUTPUT
(Connect to the outdoor power circuit board (TB-L1, L2, L3))
54
CNCT
Primary current
(Connect to the
outdoor power
circuit board (CN5))