Mains Electricity Connection - CDA DC740 Manual For Installation

Built-under double oven
Table of Contents

Advertisement

Mains Electricity
Connection
Warning! This appliance must be
earthed
To connect this appliance to a UK
2
3
1
standard mains supply, connect the
bridging links between 1-2-3 for the live
4
feed and 4-5 for the neutral feed.
We recommend that the appliance is
connected by a qualified electrician,
who is a member of the N.I.C.E.I.C. and
who will comply with the I.E.T. and local
fig.8
regulations.
This appliance is intended to be connected to fixed wiring and is
not suitable for connection to a 13A plug or 13A supply.
This appliance is intended to be connected to fixed wiring by a
double pole switch, having a contact separation of at least 3mm in
all poles. The switch must be positioned no further than 2m from the
appliance.
Release the two locks located at either side of the connector cover at
the rear of the appliance.
17