Operating Heater - Williams 696542 Owner's Operation And Installation Manual

Infrared vent-free natural gas space heater
Table of Contents

Advertisement

Manual Control Models
LIGHTING
INSTRUCTIONS
1.
STOP!
Read
information on the side of
heater.
2. Check that gas supply to
heater is on.
3. Push in gas control knob
slightly and turn clockwise
to
the OFF position (see Figures
15 &16).
4.
Wait five (5) minutes to clear
out
any
air. Then
gas, including near the floor.
If
you
smell
Follow "B"
in
information on the side of the
heater. If you do not smell
gas, go to the next step.
5.
Push
in
gas control knob
slightly and
turn
clockwise
to
and depress for five (5) seconds
NOTE:
The first time that the
heater
is operated after connect-
ing the gas supply , the control
knob should be depressed for
about thirty (30) seconds. This will
allow air
to bleed
from the gas
system.
6.
With control knob pressed in,
push down and release the
ignitor button. This will light
pilot. If needed, keep
ignitor button until pilot lights.
7.
Keep control knob depressed
for ten (10) seconds after
lighting pilot. If pilot goes out,
repeat steps 5, 6 and 7.
8.
To select the desired heating
level, partially press down the
control knob slightly and rotate
counterclockwise
downward pressure on the knob
while continuing to turn until the
knob locks at the desired setting
p o s i t i o n .
D o n o t
between locked positions.
OPERATING
the
safety
heater,set
ON, LOW, or
positions(see Figures 17 & 18).
Never set control knob between
locked positions. Poor combustion
and higher levels of carbon
monoxide may result.
adjust heating levels by using
the equipment shutoff valve.
smell for
Slightly press in control knob and
gas, STOP!
turn counterclockwise
the
safety
the
ON,
sitions (see Figures 17 & 18).
counter-
"PILOT/IGN"
Figure 15 - Control Knob In The
OFF Position (0696542 and
1096542)
pressing
. Release the
o p e r a t e
YOUR
HEATER
TO SELECT
HEATING LEVEL
WARNING: When running
control knob
HIGH
locked
CAUTION: Do not try to
LOW
or
HIGH po-
Figure 16 - Pilot
11
at
Figure 17 - Burner Patterns
to
Figure 18 - Burner Patterns
TO TURN OFF
GAS TO APPLIANCE
Shutting Off Heater
1.
Turn control knob clockwise
to the OFF position.
2.
Turn off all electric power to
the appliance if service is to
be performed.
Shutting Off Burner Only (Pilot
Stays Lit)
Turn control knob clockwise
to the PILOT/IGN position.
MANUAL LIGHTING
PROCEDURE
1. Remove lower front panel (see
Figure 6 page 7)
2.
Follow steps 1 through 5
under Lighting Instructions.
3.
With control knob pressed in,
strike match. Hold match to
pilot until pilot lights.
4.
Keep control knob pressed in
for 30 seconds after lighting
pilot. After 30 seconds, release
control knob.Follow step 8
under Lighting Instructions.
5.
Replace lower front panel.
0696542
1096542

Advertisement

Table of Contents
loading

This manual is also suitable for:

1096542069654110965413096542

Table of Contents