INSTALLATION
CHECKING GAS
CONNECTIONS
WARNING: Test all gas piping
and connections for leaks after
installing or servicing. Correct all
leaks at once.
WARNING: Never use an
open flame to check for a leak.
Apply a mixture of liquid soap
and water to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
Pressure Testing Gas Supply
Piping System
Test Pressures In Excess Of
1/2 PSIG (3.5 K Pa)
1. Disconnect appliance with its
appliance
main
(control valve)
and
shutoff valve from gas supply
piping system. Pressures in
excess of 1/2 psig will damage
heater regulator.
2. Cap off open end of gas pipe
where equipment shutoff valve
was connected.
3. Pressurize supply piping
tem by either using compressed
air
or opening main gas valve
located on or near gas meter.
4. Check all joints of gas supply
piping system. Apply mixture of
liquid soap and water to gas
joints. Bubbles forming show
a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment
shutoff valve to gas supply. Check
reconnected
fittings for leaks.
Test Pressures Equal To or
Less Than 1/2 PSIG (3.5 K Pa)
1.
Close equipment shutoff valve
(see Figure 13).
2.
Pressurize supply piping system
by either using compressed air
or opening
main
located on or near gas meter.
3. Check all joints from gas meter
to equipment shutoff valve (see
Figure 14). Apply
liquid soap and water to gas joints.
Bubbles forming show a leak.
4. Correct all leaks at once.
Pressure Testing Heater Gas
Connections
1. Open equipment shutoff valve
(see Figure 13).
2. Open main gas valve located on
or near gas meter.
3. Make
heater is in the OFF position.
4. Check all joints from equipment
shutoff valve to control valve
(see Figure 14 ). Apply mixture of
liquid soap and water to gas
joints. Bubbles forming show
a leak.
5. Correct all leaks at once.
6. Light
Heater, pages 10,11 and 12)
Check the rest of the internal
gas
valve
joints for leaks.
equipment
7. Turn off heater (see To Turn Off
Gas to Appliance, pages 11 and
12) .
8. Replace lower front panel.
sys-
Figure 13-Equipment Shutoff Valve
Figure 14 -Checking Gas Joints
gas valve
over tighten gas connections.
mixture of
sure
control
knob
heater
(see Operating
WARNING:
Do not
10

OPERATING YOUR HEATER

FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do
not
follow these instructions
exactly, a fire or explosion
may result causing property dam-
of
age personal injury or loss of life.
A. When lighting the pilot, follow
these instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for
gas. Be sure to smell next to
the floor because some gas is
heavier than air and will settle
on the floor .
WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
Do not touch any electric switch;
do not use any phone in your
building.
 Immediately
supplier from
phone.
Follow
supplier's instructions.
 If you cannot reach your gas
supplier, call the fire department.
C. Use only your hand to push in
or turn the gas control knob.
Never use tools. If the knob
will not push in or turn by
hand, don't try to repair it, call
a qualified service technician or
gas supplier. Force or attempted
repair may result in a fire or
explosion.
D. Do not use this appliance if any
part has been under water.
Immediately call a qualified
service technician
the appliance and to replace
any part of the control system
and any gas control which has
been under water.