Gemini GEM-P816 Installation Instructions Manual

Gemini GEM-P816 Installation Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEM-P816:

Advertisement

Publicly traded on NASDAQ
Symbol: NSSC
HARDWIRE
CONTROL PANEL/COMMUNICATOR
For use with "Classic" keypads (GEM-RP1CAe2, GEM-RP2ASe2, GEM-RP3DGTL and GEM-RP4RFC/GEM-RP4C)
and with "K Series" keypads (GEM-K1CA, GEM-K2AS, GEM-K3DGTL, and GEM-K4RF/GEM-K4)
G E M I N I
SYSTEM READY
11/01/10
R
1
B
4
C
7
C O M P UT E R I ZE D S E C U R I T Y S Y S T E M
"K Series" GEM-K1CA
GEMINI
16
A
1 2
R
B
4
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
"K Series" GEM-K3DGTL
© NAPCO 2008
R
G E M - P 8 1 6
12:06 AM
NEXT/YES
U
P
2
3
PRIOR/NO
Q
5
6
AREA
8
9 0
G
SYSTEM ARMED
ENT A1
01/01/97
12:00AM
INTERIOR
BYPASS
FIRE/TBL
SYS TBL
CHIME
NEXT/YES
3
E
D
PRIOR/NO
5 6
F
AREA
G
R
INSTALLATION
INSTRUCTIONS
WIRELESS
GEMINI
SYSTEM ARMED
READY
01/01/97
12:00AM
READY
AC ON
AC ON
A
1 2
3
R
D
B
4
5 6
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
"K Series" GEM-K2AS
16
"K Series" GEM-K4RF
NEXT/YES
E
PRIOR/NO
F
AREA
G
R
WI994E 5/08

Advertisement

Table of Contents
loading

Summary of Contents for Gemini GEM-P816

  • Page 1 "K Series" GEM-K1CA "K Series" GEM-K2AS GEMINI SYSTEM ARMED ENT A1 01/01/97 12:00AM INTERIOR BYPASS FIRE/TBL SYS TBL CHIME NEXT/YES PRIOR/NO AREA 7 8 9 0 COMPUTERIZED SECURITY SYSTEM "K Series" GEM-K3DGTL "K Series" GEM-K4RF © NAPCO 2008 WI994E 5/08...
  • Page 2: Important Notice

    Added warning on page 2 and important notice on page 8. Warning: The use of non-NAPCO wireless devices with this control panel has not been evalu- ated by UL and voids the UL listing. In addition, the performance of these devices can not be guaranteed as compatible with NAPCO control panels.
  • Page 3: Table Of Contents

    Auxiliary Power ..............12 FACTORY DEFAULT DESCRIPTION ......55 PGM Outputs ..............12 FCC STATEMENT ............57 Remote Bus ..............13 GEM-P816 WIRING DIAGRAM ........59 Earth Ground ..............13 LIMITED WARRANTY ............. 60 Basic Zone Configuration ..........14 4-Wire Smoke Detectors ..........15 2-Wire Smoke Detectors ..........15 Telephone Lines ..............16...
  • Page 4: Introduction

    Conventional LEDs and a sounder are also provided for annunciation. Data may be quickly and easily downloaded to the control panel using a PC-compatible computer with Napco's PCD- Windows Quickloader software and PCI2000 computer interface. Or, the panel may be programmed using the keypad in its secondary mode of operation.
  • Page 5: Important Note

    False Alarm Reduction Control Panel-01 Standard (SIA FAR CP-01). IMPORTANT NOTE This manual supports the keypad programming of the GEM-P816 control panel with the NAPCO "classic" GEM- RP1CAe2, GEM-RP2ASe2, and GEM-RP3DGTL keypads as well as the GEM-K1CA, GEM-K2AS, and GEM-K3DGTL "K Series"...
  • Page 6: Specifications

    The feature "Enable Residential Fire" (address 1422, option 4 / bit 3) must be programmed for ALL UL installations. To program, please refer to the GEM-P816 Programming Instructions (WI995 and WI1182) for further information. EZM Module: ..............GEM-EZM4/8: Input, 50mA Keypad Current: ............
  • Page 7: Ordering Information

    GEM-K4RF: Digital Icon Burg & Fire Keypad with Integral OI281: User Guide, GEM-K3DGTL RF Receiver. OI283: User Guide, GEM-K4 & K4RF GEM-P816: Residential UL-Listed Burg and Fire Control WI1178: Installation Manual, GEM-K4 Panel. WI1179: Installation Manual, GEM-K4RF GEM-RP1CAe2: 32-Character LCD Burg & Fire Keypad WI995: GEM-P816 Programming Instructions (using GEM- with 4 EOL Zones.
  • Page 8: Summary Of Ul Requirements

    (Fire, Police and Auxiliary) that has not been dedicated for such service covered by a supplied label if not in use. System must be tested at least weekly under AC/ NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 9: Installation

    Then, using hardware suitable for the mounting surface, add one or two screws at the right side of the keypad case directly into the wall to ensure a secure installation. Note: Do not overtighten the screws! Uneven walls may cause the keypad case to distort. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 10: Wiring

    CAUTION: Do not run telephone wiring near speaker wires; do not run keypad wiring with loop wiring. Adding Expansion Zones GEM-P816 control panel can support up to 16 zones as is, however this number may be increased to as many as 16 programmable zones using optional expansion zone modules (EZMs).
  • Page 11: Testing The System

    Note that if the signal strength is less than 3, the keypad will not beep and the strength will not be displayed. Except in the Fault-Find Mode, signal strengths less than 3 will be entered into the system log. Upon zone restore, the keypad will beep once. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 12: Wiring Connections

    2.2k Ohm resistor. To connect 8 Ohm Speakers use a Siren Driver with the proper polarity observed. NOTE: Refer to the GEM-P816 Wiring Diagram for alarm current specification. Note: In NFPA Household Fire Installations. only a single si- ren or bell can be used on this bell circuit.
  • Page 13: Remote Bus

    EARTH GROUND screw to the cabinet. NOTE: Grounding connections should avoid bends in the grounding wire whenever possible. NOTE: Do not use a gas pipe, plastic pipe or AC ground connections. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 14: Basic Zone Configuration

    ( – ) The basic zone configuration for the GEM-P816 is 8 zones. Connect as shown above to terminals 13-24. Normally Closed (N.C.) devices may be wired in series or Normally Open (N.O.) devices may be wired in parallel. Use the 2.2K Ohm end-of-line (E.O.L.) resistor in each zone, if selected in programming (refer to the GEM-P816...
  • Page 15: 4-Wire Smoke Detectors

    Two-wire smoke detectors can only be connected to zones 7 and 8. To use them, select fire zone programming option and select 2-wire smoke detector programming option for the desired fire zone 7 or 8 (refer to the GEM-P816 Programming Instructions) and set JP3 to the “2-WF” position as shown.
  • Page 16: Telephone Lines

    This line should not be connected to party lines or coin operated telephones. If connected to a line with call waiting, then call waiting interrupt numbers must be programmed into the CS Telephone Numbers (refer to the GEM-P816 Programming Instructions).
  • Page 17: Keypad Configuration Mode

    A valid number will be acknowledged by a short beep; an invalid number will be rejected by a long beep. 2. Press the button to continue or press the button to exit. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 18 Page 18 Compatibility Number (Not Applicable) THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P816 CON- Compat # 0000 TROL PANEL. DO NOT CHANGE THIS SETTING. Press the button to continue or press the button to exit. EZM Address EZM Address The keypad's internal EZM (Expansion Zone Module) may be utilized to provide four additional wired zones.
  • Page 19 Cut Jumper B to disable LCD backlighting. DISABLE SOUNDER Cut Jumper to disable the sounder. (Do not disable in UL applications). NAPCO Security Systems, Inc. 333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, call toll free: (800) 645-9445 For direct line to Technical Service, call toll free: (800) 645-9440 Internet: http://www.napcosecurity.com...
  • Page 20: Basic Operation

    GEM-RP2ASe2/GEM-K2AS displays will be similar, although abbreviated, and will scroll automatically. USER CODES & ZONE DESCRIPTIONS (Refer to the GEM-P816 Programming Instructions (WI995 and WI1182) for a detailed explanation of programming). Up to 16 personal user codes may be programmed at the keypad. NOTE: The Area Options associated with each User Code may only be programmed in the Dealer Program Mode.
  • Page 21: Arming And Disarming The System

    , then enter your user code and press . With the "K Series" keypads, enter your user code and press . Then press and hold until key- pad beeps Instant Arming will be automatically reset on disarming. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 22: Bypassing Zones

    UNBYPASSING ZONES (Unbypassing Specific Zones) To unbypass a specific zone that has been bypassed, press the button followed by the zone number. The zone will be unbypassed the next time the system is armed. NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 23: Alarm Indication

    To turn off the Chime Mode, press the NEXT/YES button at the DEACTIVATE CHIME function. Note: Chime is disabled for protected zones while armed. Never Armed zones (such as a driveway sensor) will continue to GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 24 If 24-hour zone is open at end of test, no report is sent. If a 24-hour zone is tripped and not restored during Fault Find, when the mode is exited the zone will display as "Faulted" on the keypad display. NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 25 Used on-site for remote downloading of a control-panel program from the PCD-Windows Quickloader Download soft- ware. Press the NEXT/YES button to initiate the data transfer. ENABLE DEALER MODE Refer to the chart on page 52. ENABLE USER MODE Refer to the chart on page 54. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 26: Keypad Messages

    Report Alarm, Report Codes, number. Subscriber ID Numbers, etc. must be programmed. FAULT FIND/RF SIGNAL POWER - Fault-find Mode activated. WIRELESS TROUBLE/04-NN SERVICE. Wireless transmitter supervisory failure. NN = transmitter number. NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 27: Glossary

    Alarm Outputs (See Wiring Diagram for UL requirements); Alarm Output Duration The GEM-P816 has three outputs: Alarm (Burg. & Fire), PGM1 and PGM2. The following table summarizes wiring for signaling an alarm in typical installations. See Time Selection for timeout durations.
  • Page 28 Arming can be delayed from 1 to 4 hours by pressing the button during the 15 minute Auto Arm Period until " TO DELAY AUTO " is displayed and press the number of hours to delay followed by the button. NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 29 Otherwise, the report had been sent and will be responded appropriately to by the Central Station. Cancel must be provided with a Central Station Telephone Number, proper Subscriber O/C Report ID Numbers and a valid Cancel Code to Telco 3. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 30 EZ Program menu. Access Location Cold Start, then press the button. Data Format Ask the central station which of these formats to use. Two-Digit or 4/2 Format. Some central-station receivers require that a four-digit Account Code followed by a two-digit Alarm Code be NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 31 Keypad Report Codes and System Report Codes are transmitted in the same format. Compatible Receivers. The following receivers are compatible with the GEM-P816: FBI CP220. Formats: Ademco Slow; Silent Knight Slow; Silent Knight Fast; DCI; Franklin Slow; SIA; Radionics Slow; Radionics Fast;...
  • Page 32 • If 24-hour zone is open at end of test, no report is sent (GEM-P816). If a 24-hour zone is tripped and not restored during Fault Find, when the mode is exited the zone will display as "Faulted" on the keypad display.
  • Page 33 E19 - Lug E19 is the Listen in Lug. It is an input and when it is forced low the panel will silence the keypad sounder and bell outputs so that the Veri-phone can listen to activity at the residence. See Veri-Phone (WI783): Silence All Outputs During Audio Session. Use Napco Part No. WL1 for field wiring. Easy Exit (Not evaluated by UL) While armed in the Interior Mode, Easy Exit can be initiated by pressing .
  • Page 34 Zone in a Group will only activate an alarm and send a report ONCE. After the Zone has reported, it will remain in the Group and may still initiate the Zone ANDing sequence. Enable Keypad 1 Only Programming: In version 01 of the GEM-P816 panel, programming is allowed from any keypad by default. Program to restrict programming to Keypad #1 only, if needed.
  • Page 35 A printer can be made to print all logged operations directly from the panel, when programmed for "Enable GEM-PRINT Module" and a separate Gem-Print Module is added to the panel. Include Selective Bypass In Conditional Closing/Status See Closing Report. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 36 Keyfob Control of Relay Groups 1 and 2 The GEM-P816 supports Keyfob Control of Relay groups 1 and 2. The Keyfob Aux 1 and Aux 2 buttons can be programmed to toggle on and off external Relay Groups 1 and 2.
  • Page 37 The Line-Reversal Module allows the panel to be monitored by a central station through leased lines. On alarm, the module reverses normal line-voltage polarity. For details, refer to the instructions furnished with the module. Loop Response See Zone Response Time GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 38 Programmable by zone, this feature will cause an alarm to sound only at the keypad for the duration of the programmed Abort Delay (see Abort Delay; Time Selection). After the delay has elapsed, the alarm output will activate and a report will be sent. On a system NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 39 Universal Hi-Speed 1850 30/20 SIA* Modem formats Ademco Point ID* Pager *These formats do not use programmable codes, but Event ID Codes to identify the type of zone and alarm as follows: 1 – Fire GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 40 Any or all zones (1-16) programmed for Selective Bypass may be removed from the system, but each must be removed separately. Refer to BYPASSING ZONES in Section 3 for operation. Security Bypass: Recommended for commercial applications, requires en- NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 41 If reporting events, program Subscriber ID Numbers for the area for each telephone number used. Subscriber ID numbers must be programmed for the area and telephone number, even if all are the same. Start with the left-most location. Sum Check See Data Format GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 42 Feature and (2) the CP-01 Requirement: • Swinger Shutdown (NAPCO Programming Feature): Program a zone with this feature to allow only three alarms per arming period. Auto-Reset must also be programmed for the zone for this feature to work. Enable 2 Count Swinger Shutdown: Same as Swinger Shutdown (NAPCO Programming Feature) above, but enables two alarms per arming period instead of three.
  • Page 43 Test Timer; Cancel Next Test Timer Report on Any Report The test timer schedule is programmed via the Easy Program Menu and using Napco's Quickloader Software. If "Test Timer" is programmed, an automatic test report will be transmitted to the central station on the scheduled day(s) at the scheduled time. To report test timer, select Report Test Time to Telco 1 or 3 and program a report code.
  • Page 44 Zone Anding for the entire Group. If "Enable Local Alarm on First ZoneAND Trip" is programmed, a trip on any Zone of the Group will cause an alarm output and alarm display at the keypad; there will be no communication to the central station. Note: If "Enable NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 45 Note: Do not program a Day Zone as a 24-Hour Zone. 24 Hour Day Zone Trouble--Normally used for a hidden N/C panic button that when pressed, trips an alarm. Switch open = alarm. Short or cut in the loop = trouble. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 46: Standby-Battery Calculation Worksheet

    (Alarm Time) (Box 3) Alarm current drawn in alarm. Alarm Time in Hours. Example: For a 15 minute alarm timeout, Alarm Time = 15/60 = 0.25. MINIMUM REQUIRED BATTERY CAPACITY = BOX 2 + BOX NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 47: Wiring Legend

    Should removal of the circuit board be necessary, use this wiring legend to relocate wire leads to their proper terminals. Enter wire identification number or color code in WIRE NUMBER column and enter wire function in DESCRIPTION column (optional). TERMINAL WIRE NO. DESCRIPTION GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 48: Keypad Programming Modes

    Follows Test Timer Always TO ARM IN 1-4HRS/PRESS 1-4 TO DELAY AUTO ARM/PRESS 1-4 If Auto Arm? Always ACTIVATE PROGRAM ACTIVATE DOWNLOAD Always Repeat N/A means Not Available. Press button to Exit at any time NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 49: Dealer Mode

    TO ARM IN 1-4HRS/PRESS 1-4 Always If Auto Arm? TO DELAY AUTO ARM/PRESS 1-4 Always ACTIVATE PROGRAM ACTIVATE DOWNLOAD Always Repeat EASY MENU MODE (See Next Page) Press button to Exit at any time N/A means Not Available. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 50: Easy Menu Mode

    See WI for Info Rcvr Format press . Press again to silence any Enter user code system troubles. XMIT#+CS P KF A XMIT#+CS OP 01 (ZONE DESCRIPTIONS) ** Enter Date** Enter Time ** Dealer Code Test Timer Repeat NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 51: User Mode

    ZONE DESCRIPTIONS * DATE * TIME * (01-32) * Not avialable in GEM-RP2AS/RP2ASe/RP2ASe2 keypads. To enter Date and Time, GEM-RP1CAe2 keypad (version 6 or Press button to Exit at any time greater) must be used. GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 52: Keypad Configuration Mode

    (“01 OUT OF SYSTEM”) Return Jumper JP1 * from Pins 2-3 to Pins 1-2 (“SYSTEM READY”) * JP1 is located at the top center of the circuit board. ** Not available in the GEM-P816. NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 53: Quick Reference Chart

    · 2 · · · · · ·)* (2053 · 2 )** 1424, Bit 0 Unvacated Premises. Convert from Away to Stay based on no egress through exit door …default is enabled. (GEM-P816 panel--This feature is Automatic Interior Bypass/ Easy Exit). (1424 1 ·...
  • Page 54 • At least one Exit/Entry zone must be programmed for each area. (SIA CP-01 Specification 4.2.1) • The GEM-P816 control panel and at least one GEM-RP1CAe2/GEM-K1CA , GEM-RP2ASe2/GEM-K2AS or a GEM-RP3DGTL/GEM-K3DGTL must be installed. • The following optional accessories support the SIA False Alarm Reduction (FAR) classification, and may be used if desired: GEM-EZOUT8, GEM- RB3008, GEM-RM3008, GEM-EZM8, GEM-EZM4/8, GEM-RECV8/16/32, GEM-TRANS2, GEM-PIR, GEM-SMOKE, GEM-HEAT, GEM-KFOB.
  • Page 55: Factory Default Description

    Page 55 GEM-P816 FACTORY DEFAULT DESCRIPTION The Factory Program of the GEM-P816 will change with the release of the new version that complies with Security Industry Asso- ciation False Alarm Reduction Control Panel-01 Standard (SIA FAR CP-01). Out of Box Panel Operation...
  • Page 56 After exiting the Easy Program Mode, the installer could complete the installation. Subsequent entering of Dealer Program Mode allows only a subset of the Easy Program menu that prevents the existing program from being deleted, but allows the system to be expanded. NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 57: Fcc Statement

    GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 58 Page 58 NOTES NAPCO Security Systems GEM-P816 Installation Instructions...
  • Page 59: Gem-P816 Wiring Diagram

    Page 59 GEM-P816 WIRING DIAGRAM Smoke Detector Compatibility Identifier GEM-P816 GEM-P816 Installation Instructions NAPCO Security Systems...
  • Page 60: Limited Warranty

    NAPCO will, within said period, at its option, repair or replace any In no event shall NAPCO be liable for an amount in product failing to operate correctly without charge to the excess of NAPCO's original selling price of the product, original purchaser or user.