Instructions for the Installer

Engineers technical data

OVERALL DIMENSIONS
CUT OUT DIMENSIONS
SUPPLY CONNECTIONS
Gas:
Electric:
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
Burner
Dia. Tap By-pass
1/100 mm
BURNER
RAPID
(large)
POSITION
MAX
kW
3.0
m
3
/h
0.286
0.062
119
Adjust.
1/100 mm
kW
2.8
g/h
202
86
1/100 mm
Ignition HT Spark
Rear Left Burner (semi rapid)
Front Left Burner (auxiliary)
Rear Right Burner (semi rapid)
Front Right Burner (rapid)
Central Burner (Ultra-rapid Double-crown)
SEMI-RAPID
AUXILIARY
(medium)
MIN
MAX
MIN
MAX
0.65
2.0
0.45
1.0
0.190
0.043
0.095
96
Adjust.
70
0.65
2.0
0.45
1.0
47
144
32
72
40
71
32
50
APPLIANCE CLASS
APPLIANCE CATEGORY
APPLIANCE GAS SUPPLY
ULTRA-RAPID
(small)
(double-crown)
MIN
MAX
MIN
0.33
3.5
1.2
0.031
0.333
0.114
Adjust.
136
Adjust.
0.33
3.2
1.2
24
231
86
28
88
56
9