Page 1
IT-230 RS-422 Interface Module v2.0 Installation Manual Warning: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer.
WARNING Please Read Carefully Note to Installers This Warning contains vital information. As the only individual in contact with system users, it is the installer’s responsibility to bring each item in this Warning to the attention of all users of this system. System Failures Motion Detectors This system has been carefully designed to be as effective...
“panel” throughout this document. The IT-230 Interface shall be installed in the location specified in these instructions. The equipment enclosure must be fully assembled and closed, with all the necessary screws/tabs, and secured to a wall before opera- tion.
Insert the 5 standoffs into the holes on the left side of the Panel as shown in Figure 1 (left view). d. Orient the IT-230 with the standoffs on left side of Panel and push the IT-230 firmly and evenly onto the standoffs until it is securely attached to the Panel.
NOTE: Do not attach any wires to the “DEF” terminal on the IT-230. RS-422 Connection for C24-HUB 3. Terminate the previously run RS-422 cable from the C24-HUB to the IT-230 TB2 as follows: See Figure 2. a. Connect the TX+ wire to the RX+ terminal on the IT-230.
This trouble will be indicated when communication between the IT-230 module and the Panel fails. If the module can not communicate with the panel (e.g., loss of power to the panel) the IT-230 will send a Panel Absent Trouble (Sec- tion [023]) event message to the Change to C24-HUB.
Default (04) The module can be configured to send IT-230 Events in SIA or CID format. Program 03 for CID. Program 04 for SIA. The SIA communication format follows the level 2 specifications of the SIA Digital Communication Standard - October 1997.
[671] Lifestyle Event Toggle This section determines the events recorded in the Lifestyle Log. When the lifestyle log buffer is 75% full, the IT-230 will connect to the server and upload the lifestyle information. The log can buffer 1,000, variable length, lifestyle events.
Default (ON) [4] Lifestyle Log System Maintenance Default (ON) [5] Lifestyle Log System Test Default (ON) [6] Lifestyle Log IT-230 Events Default (ON) [7]-[8] Reserved Default (ON) 64 Zone Notification Toggle Options [682] Notification Zone 1 - 8 Toggle Options The default for each Notification Zone Toggle is ON.
[999] Software Default Default (99) Software default allows the installer to refresh the unit after changes and also return the IT-230 to default state. 00: Default Module. All programming Sections in module reset to factory settings. NOTE: This will erase all existing programming of the IT-230.
Page 13
PARTICULAR PURPOSE) AND OF ALL OTHER OBLIGA- any changes or modifications to the Software, without the writ- TIONS OR LIABILITIES ON THE PART OF DSC. ten permission of an officer of DSC. You may not remove any MAKES OTHER WARRANTIES.
Page 14
The laws of some jurisdictions limit or do not allow the delivery. In such cases, DSC can replace or credit at disclaimer of consequential damages. If the laws of its option.