GS3055-I CF GSM-GPRS INTERFACE Installation Manual WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer.
Weight: ................. 5.8Kg (12.8 lbs) (including standby battery) This equipment, GS3055-I CF, is fixed and shall be installed by Service Persons only (Service Person is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons) according to the local rules and regulations.
Sur-Gard System III, System II, or SG-SYSTEM I receiver. By connecting a GS3055-I CF to a control panel's standard PSTN interface, telephone based Contact ID signals are decoded and seamlessly routed through the GPRS network to any of the compatible receiver options.
Identification of Parts The numbers in square brackets [ [ [ [ [ ] ] ] ] ] in this manual refer to the main parts of the GS3055-I CF (see Fig.1 below) described in this section. WARNING!: HIGH VOLTAGE...
4. Ensure the SIM card is placed in its socket [6 6 6 6 6 ] 5. Power up the GS3055-I CF module [4 4 4 4 4 ] and check signal strength on status LEDs [7 7 7 7 7 ].
+12V/COM - Special application output circuit, power limited, connect to GS3055-I CF power input circuit. Connect the +12V output to +12V input on the GS3055-I CF module and the COM output to the - 12V input on the GS3055-I CF module.
• if the land line is still down if the land line is still down if the land line is still down, it will continue to simulate the land line until it is restored. The GS3055-I CF will not switch during ongoing calls.
The GS3055-I CF has 4 open collector outputs, switched to ground, capable of a maximum of 50mA. Internal events on the GS3055-I CF can trigger the outputs to turn on an LED or activate an input on the alarm control panel. The default settings are as follows:...
Maintain at least 1” (25.4mm) separation. A minimum 1/4” (6.4mm) separation must be maintained at all points between Power Limited wiring and all other Non-Power Limited wiring. Route wires as indicated in the diagram. Fig. 2 - GS3055-I CF Module Wiring Diagram WARNING! HIGH VOLTAGE.
Page 11
GS3055-I CF will generate a trouble signal transmission to the monitoring station. 3. Output 4 on the GS3055-I CF must be set as “Active High”. Supervision Power Supply...
Page 12
Incidence of Harm Le nombre équivalent de sonneries (REN) de cet appareil terminal est 0.0. Le REN attribué à If this equipment GS3055-I CF causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance chaque équipement terminal fournit une indication sur le nombre maximum de terminaux...