Purple; Off; Red/Yellow - Ariens 915055 Service Manual

915 zoom ezt & izt
Table of Contents

Advertisement

Diode check out: Diodes are checked with an ohm
meter set on the diode check, and should only pass
voltage in one direction. If it passes voltage in both
directions or not at all the diode is bad and needs to be
replaced.
.
Key Switch
B
A
S
L
Contact resistance is 0.1-0.3 ohms when correct.
Seat Switch

Red/Yellow

Purple

Normally open contacts manually activated. contact resistance is 0.1-0.3 ohms when correct.
PTO Switch
Brown
Purple/White
Purple
Red/Green
Brown/Yellow
2 sets of contacts, one normally open, one normally closed. Contact resistance is 0.1-0.3 ohms when correct.
Left Hand Neutral Switch (A)
Brown/Yellow
White
Normally open contacts manually activated. Contact Resistance is 0.1-0.3 ohms when correct.
(A) Measure with steering arms in neutral.
Right Hand Neutral Switch (A)
Red/Green
White
Yellow/Red
Normally open contacts manually activated. Contact Resistance is 0.1-0.3 ohms when correct.
(A) Measure with steering arms in neutral.

Off

11.50-13.00 Volts
11.50-13.00 Volts
11.50-13.00 Volts
11.50-13.00 Volts
Off
11.50-13.00 Volts
11.50-13.00 Volts
Off
Connected to PTO Clutch
11.50-13.00 Volts
11.50-13.00 Volts
Off
11.50-13.00 Volts
Off
11.50-13.00 Volts
11.50-13.00 Volts
11.50-13.00 Volts
11 - 44
Run
11.50-13.00 Volts
11.50-13.00 Volts
11.50-13.00 Volts
11.50-13.00 Volts
Run
11.50-13.00 Volts
11.50-13.00 Volts
Run
11.50-13.00 Volts
11.50-13.00 Volts
11.50-13.00 Volts
11.50-13.00 Volts
Run
Start
11.50-13.00 Volts
11.50-13.00 Volts
Run
Start
11.50-13.00 Volts
11.50-13.00 Volts
11.50-13.00 Volts
Start
Start
Start