Electronic Ignition - MHSC 400BBVNV Installation & Operating Instructions Manual

B-vent series natural vent gas fireplace
Table of Contents

Advertisement

TROUBLESHOOTING

ELECTRONIC IGNITION

START
1.   T urn gas suppl y  of f .
2.   T urn O N /O F F  sw itch  to " O N "
  P ow er to modul e ( 24V N ormal )
YES
 
I s th ere a spark  across 
 ignitor sensor gap?
YES
T urn on gas.  
D oes pil ot b urner l igh t?
YES
D oes spark  stop w h en pil ot is l it?
YES
D oes main b urner l igh t?
YES
D oes sy stem run until  O N /O F F  sw itch
 is in " O F F "  position?
YES
END OF TROUBLESHOOTING
BBV, SBV Series Natural Vent Gas Fireplaces
C h eck :   L ine v ol tage ( 120VA C )
NO
 
L ow  v ol tage transf ormer ( 19. 5 minimum VA C )
 
O N /O F F  sw itch
 
W iring connections 
  U npl ug ignition l ead and 
NO
 
ch eck  spark  at modul e   
 
( 24VA C  normal ) .  
 
I s spark  O K ?  
 
YES
A .  C h eck  ignition cab l e ground w iring, ceramic insul ator and gap.  
Correct if necessary.
B.  D oes ignition cab l e sh ow  signs of  mel ting or b uck l ing?   
Take protective action to shield cable and boot from 
excessive temperatures. 
A .  A re al l  manual  gas v al v es open?
NO
  A re suppl y  tub ing and pressure good?
  A re pil ot b urner orifies b l ock ed?
B.  C h eck  el ectrical  connections b etw een modul e and pil ot 
operator on gas control .
C .  C h eck  f or 24VA C  across P V- M VP V terminal s.
  If voltage is correct, replace gas control.
  If voltage is not correct, replace module. 
NOTE: If Module goes into lockout, reset system.
NO
A .  C h eck  continuity  of  ignition cab l e and ground w ire.
B.  C l ean flame rod.
C .  C h eck  el ectrical  connections b etw een flame rod and modul e.
D .  Is ceramic flame rod insulator cracked?
E .  Is pilot flame a steady blue? Does flame cover flame rod?
  If not, adjust pilot flame. Replace module if problem persists.
A .  C h eck  f or 24VA C  across M V- M VP V terminal .  
NO
  Replace module if there is no voltage. 
B.  A re el ectrical  connections b etw een modul e and gas 
control  good?   
If connections are good, replace gas control or gas
control operator.
NO
NOTE: If Module goes into lockout, reset system.
A .  C h eck  continuity  of  ignition cab l e and ground w ire.
  NOTE: If ground is poor or erratic, shutdown may
occasionally occur even though operation is normal at
time of checkout. 
B.  Is pilot flame a steady blue? Does flame cover flame rod?
F P 2031
E l ectronic trb l sh t
 
R epl ace modul e
NO

Hide quick links:

Advertisement

Table of Contents
loading