Operating Instructions and Installation
3-2-2(a) Fixing the Installation Plate
Installation plate
(Unit : mm)
255
512
(Unit : mm)
3-2-2(b) Purging the Unit
3-6
1. Determine the position of the pipe and drain hose hole
using the right figure and drill the hole with an inner
diameter of 65mm so that it slants slightly downwards.
Pipe hole
(ø65mm)
2. If you are fixing the indoor unit to a... Then follow Steps...
Wall
Window frame
3. Fix the installation plate to the wall in a manner appro-
priate to the weight of the indoor unit.
If you are mounting the plate on a concrete wall with
325
anchor bolts, the anchor bolts must not project by more
than 20mm.
415
4. Determine the positions of the wooden uprights to be
attached to the window frame.
5. Attach the wooden uprights to the window frame in a
manner appropriate to the weight of the indoor unit.
6. Using tapped screws, attach the installation plate to the
wooden uprights, as illustrated in the last figure oppo-
site.
On delivery, the indoor unit is loaded with an inert gas.
All this gas must therefore be purged before connecting the
assembly piping. To purge the inert gas, proceed as fol-
lows.
Unscrew the caps at the end of each pipe.
Result : All inert gas escapes from the indoor unit.
To prevent dirt or foreign objects from getting into
the pipes during installation, do NOT remove the
caps completely until you are ready to connect the
piping.
3.
4 to 6.