Samsung AS18A9(0)RCFD Owner's Instructions Manual

Samsung AS18A9(0)RCFD Owner's Instructions Manual

Split-type room air conditioner (cool)

Advertisement

Aire acondicionado doméstico sistema Split (Refrigeración)
E S F
DB98-15772A(3)
Split-type Room Air Conditioner (Cool)
Climatiseur de type Séparé (Refroidissement)
OWNER'S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D'UTILISATION
Indoor Unit
AS07A5(6)MA
AS09A5(6)MAF
AS12AA(B)MCF
AS18A9(0)RCF
AS18A9(0)RCFD
AS24A1(2)RC
AS24A1(2)RCD
Outdoor Unit
US07A5(6)MA
US09A5(6)MAF
US12AA(B)MCF
US18A9(0)RCF
US18A9(0)RCFD
US24A1(2)RC
US24A1(2)RCD

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AS18A9(0)RCFD

  • Page 1 Aire acondicionado doméstico sistema Split (Refrigeración) Climatiseur de type Séparé (Refroidissement) E S F DB98-15772A(3) OWNER’S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D’UTILISATION Indoor Unit Outdoor Unit AS07A5(6)MA US07A5(6)MA AS09A5(6)MAF US09A5(6)MAF AS12AA(B)MCF US12AA(B)MCF AS18A9(0)RCF US18A9(0)RCF AS18A9(0)RCFD US18A9(0)RCFD AS24A1(2)RC US24A1(2)RC AS24A1(2)RCD US24A1(2)RCD...
  • Page 2: Safety Precautions

    Safety Precautions The following safety precautions must be taken when using your air conditioner. WARNING URING OPERATION ISPOSING OF THE UNIT THERS Register your product at www.samsung.com/global/register Risk of electric shock. Can cause injury or death. remote electric power supplies before servicing, installing or cleaning.
  • Page 3: Table Of Contents

    Temperature and Humidity Ranges ....20 Cleaning Your Air Conditioner ......21 Solving Common Problems .
  • Page 4: View Of The Unit

    View of the Unit The design and shape are subject to change according to the model. Indoor Unit Air filter (under the grille) Timer indicator STANDARD indicator NATURE indicator Air flow blades (outlet) Air Inlet For details on the 5 Way, refer to page 9. Remote Control Sensor SAVING indicator SILENCE indicator...
  • Page 5 Outdoor Unit US07A5(6)MA Air Outlet Outdoor Unit US12AA(B)MCF Air Outlet Outdoor Unit US18A9(0)RCF Air Outlet Outdoor Unit US24A1(2)RCD Air Outlet US09A5(6)MAF Air Inlet(Rear) Connection Valve Air Inlet(Rear) Connection Valve US18A9(0)RCFD US24A1(2)RC Air Inlet(Rear) Connection Valve Air Inlet(Rear) Connection Valve...
  • Page 6: Remote Control-Buttons And Display

    Remote Control - Buttons and Display Remote control transmission indicator Operating mode AUTO, DRY, Temperature setting Turbo mode Sleep mode Fan speed Air flow direction On Timer setting Off Timer setting Battery discharge indicator 5 Way selection button COOL, FAN) Mode selection button (AUTO, COOL, DRY, FAN) Temperature adjustment...
  • Page 7: Getting Started

    Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features. The booklet is organized as follows.
  • Page 8: Inserting The Remote Control Batteries

    Inserting the Remote Control Batteries Installing the Remote Control Holder You must insert or replace the remote control batteries when : You purchase the air conditioner The remote control does not work correctly Use two AAA, LR03 1.5V batteries. Do not use old batteries or different kinds of batteries together.
  • Page 9: Way Function

    5 Way Function You can select the 5 Way function with operating mode of the air conditioner for more comfortable circumstances. You can use the 5 Way function with the indoor unit as well as the remote control. Thus, you can use this function even though you have lost your remote control.
  • Page 10: Selecting The Automatic Operating Mode

    Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed.
  • Page 11: Cooling Your Room

    The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. IMPORTANT The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: Plugged in Stopped lt will start up normally after three minutes.
  • Page 12: Changing The Room Temperature Quickly

    If necessary, press the (On/Off) button. Result: The 5 Way indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. Press the button.
  • Page 13: Removing Excess Humidity

    If necessary, press the (On/Off) button. Result: The 5 Way indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. IMPORTANT The air conditioner is fitted with a protection mechanism...
  • Page 14: Airing Your Room

    If necessary, press the (On/Off) button. Result: The 5 Way indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps. If the is not displayed at the top of the remote control,...
  • Page 15: Adjusting The Air Flow Direction Vertically

    Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. Press the button one or more times as required.
  • Page 16: Setting The On Timer

    To cancel the On Timer, press the timer setting disappears. Press the (Set/Cancel) button. If you want to turn on the air conditioner before the timer reaches the setting time, press the button one or more times until button until the button one or more times until the (On/Off) button.
  • Page 17: Setting The Off Timer

    The air conditioner will switch off automatically when the counter displayed on the remote control reaches the set time and disappears the Off timer setting. If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours: 1. Press the button until ‘2.0 Hr’...
  • Page 18: Setting The Sleep Timer

    Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of six hours. If you wish to switch the unit off at a specific time, refer to page 17.
  • Page 19: Operating Recommendations

    Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, Be sure which model you have purchased because some air conditioners do not restart automatically.
  • Page 20: Temperature And Humidity Ranges

    Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... High temperatures Low temperatures High humidity levels Mode Outdoor Temperature Indoor Temperature Cooling 70°F to 109°F approx.
  • Page 21: Cleaning Your Air Conditioner

    Reassemble the air filters and the front grille. If you have not used the air conditioner for a long period of time, set the fan going for three to four hours to dry the inside of the air conditioner thoroughly.
  • Page 22: Solving Common Problems

    Check whether the TIMER indicator on the indoor unit is switched on. If so: - Wait until the switch-on time is reached and the air conditioner starts up automatically - Cancel the timer (see pages 16 and 17 for further details) Check that there are no obstacles between you and the indoor unit.
  • Page 23: Installing A Filter (Option)

    Installing a Filter (Option) The air conditioner can be fitted with a deodorizing and Bio-Pure filter to remove minute dust particles or odours. The service life of the filter is approximately three months depending on the time during which the air conditioner is used.
  • Page 24: Technical Specifications

    Technical Specifications MODEL Capacity Cooling Performance Ratings SEER Moisture Removal Air FLOW(Cooling, HIGH) Sound Rating-Outdoor Electrical Power source Data Min.Ampacity Cooling Watts Connections Refrigeration Lines Liquid Line O. D. Suction Line O.D. Factory Pre-charge Max. Line length Max. Height Difference INDOOR UNIT Dimensions &...
  • Page 25 Max. Height Difference INDOOR UNIT Dimensions & Weight inch(mm) W x H x D Net Weight OUTDOOR UNIT W x H x D inch(mm) Net Weight AS18A9(0)RCF / AS18A9(0)RCFD Btu/h 18000 10.0 Pts/h 208-230V~, 60Hz 1770 Flare (6.35) (12.70) ft(m) (7.5)
  • Page 26 THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: ELECTRONICS Printed in Korea...

Table of Contents