en | RADION receiver SD
The transformers mentioned above are Primary Rated 120VAC, 60 Hz, 0.48 Amps, Secondary
16.5VAC, 40VA.
When selecting a suitable 18VAC Class 2 plug-in transformer, the following transformers are
suggested:
Notice!
For UL installations when transformer is used, restraining tab is to be connected.
Notice!
For UL installations when a repeater is installed, a minimum of two repeaters must be
installed for proper signal routing.
Information related to the internal standby battery is as follows:
Notice!
For standby battery to be operative, the tamper switch is required to be engaged.
Standby battery is capable of providing 72 hours of standby power to the RF repeater for a UL
Burglar Alarm Installation (Bank Safe and Vault).
RADION glassbreak
Notice!
The RFGB-A has not been investigated by UL, and not part of a UL Listed system.
RADION TriTech
Notice!
Pet Immunity has not been evaluated by UL.
Notice!
Draft and Insect Immunity has not been evaluated by UL.
2014.03 | 06 | F.01U.261.834
TDC Part No DA-22-18, Primary Rated 120VAC, 60 Hz, 30VA, Secondary Rated 18VAC, 1.3
Amps, 22VA.
Power/voltage (Standby Battery): Rated 3.7 VDC, 3050mAH, EVE ENERGY CO Part No
P0046-LF (Not user replaceable)
24 Hours for Household Fire Warning Systems
8 Hours for HOLD UP Burglar Alarms
4 Hours for Burglar Alarm Mercantile Installations