Datalogic PowerScan M8300 Quick Reference Manual

Datalogic PowerScan M8300 Quick Reference Manual

Hide thumbs Also See for PowerScan M8300:

Advertisement

PowerScan® M8300 Readers
Quick Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic PowerScan M8300

  • Page 1 PowerScan® M8300 Readers Quick Reference Guide...
  • Page 2 An Unpublished Work - All rights reserved. No part of the contents of this documenta- tion or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes.
  • Page 3: Updates And Language Availability

    The latest drivers and documentation updates for this product are available on Internet. Log on to : www.datalogic.com Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana.
  • Page 4: Scan Line Position

    Using PowerScan® M8300 ® USING POWERSCAN M8300 ® The PowerScan M8300 series readers can be used with either an BC-80X0 cradle or Stargate™ radio base station to build a Cordless Reading System for the collection, decoding and transmission of barcoded data. ®...
  • Page 5: Aiming System

    Using PowerScan® M8300 AIMING SYSTEM ® PowerScan M8300 provides an aiming system. If enabled, a partial trigger press produces a red spot, which should be aimed over the code center to get the best reading performance, see figure (1) above. By completely pressing the trigger the scan line appears to start the code scanning (2).
  • Page 6: Charging The Batteries

    Charging the Batteries CHARGING THE BATTERIES Once the BC-80X0/C-8000 is powered, you can charge the reader's batteries. ® Place the PowerScan M8300 into the BC-80X0 cradle or the C-8000 battery charger. The "Reader" LED on the cradle/battery charger turns red. The battery is completely charged when the "Reader"...
  • Page 7 Charging the Batteries SETUP ® PowerScan M8300/BC-80X0 Point-to Point Configuration Connect an BC-80X0 cradle to the Host. For installation and connection infor- mation see the BC-80X0 Quick Reference Manual. ® M8300 battery using an BC-80X0 or the Charge the PowerScan C-8000 charger as described in this Quick Reference manual.
  • Page 8: Powerscan ® M8300 Configuration

    PowerScan® M8300 Configuration ® POWERSCAN M8300 CONFIGURATION ® PowerScan M8300/BC-80X0 Point-to-Point Setup A rapid configuration procedure has been devised for point-to-point applications where a single reader is associated exclusively with its own BC-80X0 base station and where it is not necessary to set the Date and Time parameters. A special pre-printed bind-address label provided in the BC-80X0 base station ®...
  • Page 9: Powerscan ® M8300/Bc-80X0 Stand Alone Setup

    PowerScan® M8300 Configuration ® POWERSCAN M8300/BC-80X0 STAND ALONE SETUP ® When the BC-80X0 cradle is connected and powered, configure the PowerScan M8300 by reading the following codes in the given sequence and follow the instructions. Note: for the numeric code selection of steps 3, 4, and 5 use the table at the end of this Quick Reference.
  • Page 10 PowerScan® M8300 Configuration ® Read the Bind code to pair the PowerScan M8300 to the BC-80X0 cradle. The reader is dedicated to the cradle. Any previously bound reader will be excluded. To connect several readers to the same cradle see the following section "Using Multiple Readers with Same Cradle".
  • Page 11: Using Multiple Readers With Same Cradle

    PowerScan® M8300 Configuration USING MULTIPLE READERS WITH SAME CRADLE If you want to use several readers associated with the same cradle, you must first Bind the cradle with one of the readers (see previously described configuration procedure). Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join.
  • Page 12: Powerscan ® M8300/Star-System™ Setup

    PowerScan® M8300 Configuration ® POWERSCAN M8300/STAR-SYSTEM™ SETUP ® The following procedure allows configuring a PowerScan M8300 reader to communicate with various STAR-System™ devices such as Stargate™ RF base stations: ® Restore PowerScan M8300 Default Ì$+$*oÎ Enter Configuration Ì$+;Î Set Date ÌIA%Î...
  • Page 13 PowerScan® M8300 Configuration Set Radio Address ÌRF8Î ® four digits from the Numeric Table for the PowerScan M8300 Address (from 0000 to 1999). All readers used in the same area must have different addresses. Set First STAR-System™ Address ÌRSRÎ four digits from the Numeric Table in the range 0000 to 1999 Set Last STAR-System™...
  • Page 14: Powerscan ® M8300 Default Configuration

    PowerScan® M8300 Default Configuration ® POWERSCAN M8300 DEFAULT CONFIGURATION DATA FORMAT code identifier disabled, field adjustment disabled, code length not transmitted, character replacement disabled CODE SELECTION enabled codes • EAN 8/EAN 13 / UPC A/UPC E without ADD ON check digit transmitted, no conversions •...
  • Page 15: Technical Features

    Reading Field Width see reading diagram (typical) Max. Resolution 0.076 mm (3 mils) 0.19 mm (7.5 mils) PCS minimum (Datalogic Test Chart) 13.5°  0.7 Scan Angle 42° Laser Safety Class 2 (EN 60825-1 / CDRH) Radio Features European Models...
  • Page 16: Reading Diagrams

    Reading Diagrams READING DIAGRAMS PowerScan® M8300 108 cm 0.13 mm (5 mils) 0.19 mm (7.5 mils) 0.25 mm (10 mils) 0.33 mm (13 mils) 0.38 mm (15 mils) 0.50 mm (20 mils) 1.00 mm 1.38 mm (40 mils) (55 mils) ®...
  • Page 17: Warranty

    3 years from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic has the faculty to repair or replace the product; these provisions do not prolong the original warranty term. The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.
  • Page 18: Fcc Compliance

    FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.
  • Page 19: Led Class

    Compliance The laser scanner utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc.
  • Page 20: Weee Compliance

    Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com.
  • Page 21 Numeric Table NUMERIC TABLE Ì01Î Ì12Î Ì23Î Ì34Î Ì45Î Ì56Î Ì67Î Ì78Î Ì89Î Ì9:Î Quick Reference Guide...
  • Page 22 Numeric Table NOTES PowerScan® M8300...
  • Page 23 Datalogic Scanning, Inc. 959 Terry Street Eugene, OR 97402 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el PowerScan Mxxx; Cordless Barcode Reader e tutti i suoi modelli and all its models et tous ses modèles...
  • Page 24 Telephone: 49 (0) 61 51/93 58-0 Telephone: (65) 6435-1311 germany.scanning@datalogic.com singapore.scanning@datalogic.com India Spain and Portugal Datalogic Scanning India Datalogic Scanning Sarl Sucursal en España Telephone: 91- 22 - 64504739 Telephone: 34 91 746 28 60 india.scanning@datalogic.com spain.scanning@datalogic.com Italy United Kingdom...