Ras-18Ufp-Es / Ras-18Ua-Es - Toshiba RAS-18UFHP-ES Service Manual

Under ceiling/console type air-conditioner
Hide thumbs Also See for RAS-18UFHP-ES:
Table of Contents

Advertisement

5-2. RAS-18UFP-ES / RAS-18UA-ES

0.39m
(Connecting pipe)
∅12.70 mm
0.39m
(Flexible pipe)
∅12.70 mm
O.D.:12.70 mm
Packed valve
(∅12.70)
Accumulator
Compressor
PA225X3F-4L
50Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Indoor unit
Evaporator
Multi blade fan
P
Condenser
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
0.9
1.0
0.6
T
Refrigerant
R-410A 1.20 Kg
Mark (
Surface temp. of heat
exchanger interchanging
pipe T (°C)
10.0
13.0
2.0
– 16 –
FILE NO. SVM-02009
0.49m
(Connecting pipe)
∅6.35 mm
O.D.:6.35 mm
Packed valve
(∅6.35)
Muffler
Capillary tube
∅1.7x350S
) means check points of Gas Leak
Ambient temp.
conditions DB/WB
Fan speed
(°C)
(indoor)
Indoor
Outdoor
High
27/19
High
32/23
Low
21/15
35/24
43/26
21/15