Download Print this page

Care Instructions - American Standard MOMENTS 2506.101 Installation Instructions Manual

Monoblock lavatory faucet with speed connect drain

Advertisement

10
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks.
if necessary.
11
SERVICE
Turn on valve and allow water supply temperatures to
stabilize. Move HANDLE to full HOT setting. Check
water temperature.
To decrease hot limit temperature setting:
Pull out Plug Button (1), loosen Handle Set Screw (2)
and remove Handle (3) from Cartridge Stem (5). Remove
Cartridge Cover (4).
Lift Setting Insert (6), rotate counterclockwise one notch
and replace. Check water temperature and repeat if
necessary. Unit is factory set at "0" (full HOT water). As
the setting number increases, the more cold water is
supplied in the full HOT handle position.
Replace Cartridge Cover (4). Align Handle (3) and tighten
Set Screw (2). Replace Plug Button (1).
12

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
Tighten
1
4
4
WASTE
OUTLET
2
3
4
2
setting 0 - setting
5
insert covers blend
6
Blend control
ON
1
OFF
COLD
HOT
5
2
"P" TRAP
TOP
CARTRIDGE
HOTTEST
Blend control
control setting
TOP
number 1 - 4
COOLEST
setting 4
M 9 6 8 9 4 1 R e v . 1 . 2
3
6

Advertisement