Residential and outdoor fireplace
Table of Contents

Advertisement

F
l
iReplace
ocation
CAUTION: Do not install fireplace over carpeting.
This fireplace does not weigh more than large pieces of furniture and can normally be located near a load
bearing wall without requiring additional foundations or supports. If however, the fireplace is to be trimmed
with a heavy stone or brick facing and hearth extension, be sure the supporting structure is adequate.
Figures 5 and 6 provide dimensional details of the fireplace, required spacing to combustible walls, and some
suggested fireplace locations. When selecting a location, choose one that is away from frequently opened
doors, central heat outlets or returns, or other places where air movements may disturb the airflow around the
fireplace. Air turbulence near the fireplace may cause smoke to spill out of the fireplace opening.
F
5
iguRe
64 15/16
(MIN)
19 3/8
F
6
iguRe
6
19 3/8
53 1/8
91 7/8
(MIN)
CORNER INSTALLATION
CORNER
27 7/8
(MIN)
23 1/2
(MIN)
28
(MIN)
SCREENED OPENING
76 1/2
(MIN)
SIDE WALL INSTALLATION
* APPLIES WHEN GLASS DOORS ARE INSTALLED
FULL PROJECTION
FLUSH
1 1/2
AIR SPACE
CLEARANCE
16*