Product Information
Specifications (Cont.)
Dimensions (HWD)
Enclosure
Power Consumption
Baseline draw
With all 8 relays On
Front Panel Components
AXlink Status indicator
Device DIP switch
Relay LEDs 1-8 (Red)
Rear Panel Components
AXlink connector
Relay contacts
2
1.51" x 5.55" x 5.45" (3.84 cm x 14.10 cm x 13.84 cm)
Non-glare, high-impact black matte plastic
• 90 mA @ 12 VDC (min)
• 170 mA @ 12 VDC (max)
AXlink LED (green and blinks to indicate AXlink communication activity and
power:
• Full-Off indicates no power is being received or the controller is not
functioning properly.
• One blink per second indicates power is active and AXlink communication is
functioning.
• Full-On indicates there is no AXlink control or activity, but power is On.
An eight-position DIP switch is used to set the device number for the
AXB-REL8.
Illuminate when associated relay is closed. Relay LED's should match panel
control function.
Four-pin captive wire receives power and information via the AXlink bus and
AXlink system controller.
Eight (normally -open) isolated two-pin relay contacts 1 A @ 28 VAC or VDC:
• Relays 1-4 can share a common if use jumper"A" pins with a tab strip
• Relays 5-8 use discrete commons (wire commons individually)
AXB-REL8 Axcess Relay Controller