Physical Data - Carrier Comfort 24ACA3 Product Data

Comfort 13 series air conditioner with puron refrigerant 1---1/2 to 5 nominal tons (size 18 to 60)
Table of Contents

Advertisement

UNIT SIZE SERIES
Operating Weight (lb)
Shipping Weight (lb)
Compressor Type
REFRIGERANT
Control
Charge (lb)
COND FAN
Air Discharge
Air Qty (CFM)
Motor HP
Motor RPM
COND COIL
Face Area (Sq. ft.)
Fins per In.
Rows
Circuits
VALVE CONNECT. (In. ID)
Vapor
Liquid
REFRIGERANT TUBES* (In. OD)
Vapor (0--- 80 Ft. Tube Length)
Liquid (0--- 250 Ft. Tube Length)
* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.
Note: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
PURON 1- -STAGE AIR CONDITIONER APPLICATIONS
LONG LINE APPLICATION: An application is considered "long
line" when the total equivalent tubing length exceeds 80 ft or when
there is more than 20 ft. vertical separation between indoor and
outdoor units. These applications require additional accessories and
system modifications for reliable system operation. The maximum
allowable total equivalent length is 250Ft. The maximum vertical
separation is 200 Ft when outdoor unit is above indoor unit, and 80
UNIT
ACCEPTABLE
ACCEPTABLE
NOMINAL
LIQUID LINE
VAPOR LINE
SIZE
DIAMETERS
DIAMETERS
(BTUH)
(IN. OD)
18000
1 Stage
3/8
Puron AC
24000
1 Stage
3/8
Puron AC
30000
1 Stage
3/8
Puron AC
36000
1 Stage
3/8
Puron AC
42000
1 Stage
3/8
Puron AC
48000
1 Stage
3/8
Puron AC
60000
1 Stage
3/8
Puron AC
Standard Length = 80 ft. or less total equivalvent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guideline
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit. See
Long Line Application Guideline.

PHYSICAL DATA

18---30
24---30
135
135
156
156
4.25
4.35
1880
2200
1/12
1/10
1100
1100
9.85
9.85
20
20
1
1
3
3
5/8
5/8
5/8
5/8
Standard Application
(IN. OD)
25
50
1/2
1
2
5/8
0
0
5/8
0
1
3/4
0
0
7/8
0
0
5/8
1
2
3/4
0
0
7/8
0
0
5/8
1
2
3/4
0
0
7/8
0
0
3/4
0
1
7/8
0
0
1 1/8
0
0
3/4
0
1
7/8
0
0
1 1/8
0
0
3/4
1
2
7/8
0
1
1 1/8
0
0
30---30,50
36---30,50,60
42---30,50,60
149
166
171
189
Scroll
Puron® (R--- 410A)
TXV (Puron® Hard Shutoff)
4.75
5.25
Propeller Type, Direct Drive
Vertical
2200
2950
1/10
1/4
1100
1100
11.49
14.77
25
25
1
1
3
3
3/4
3/4
3/8
3/4
3/4
3/8
ft. when the outdoor unit is below the indoor unit. Refer to
Accessory Usage Guideline for required accessories. See Long
Line Application Guideline for required piping and system
modifications. Also, refer to the table below for the acceptable
vapor tube diameters based on the total length to minimize the
cooling capacity loss.
COOLING CAPACITY LOSS (%)
TOTAL EQUIVALENT LINE LENGTH (FT..)
Long Line Application Requires Accessories
80
80+
100
125
3
3
4
6
1
1
1
1
1
1
2
3
0
0
0
1
0
0
0
0
3
3
3
4
1
1
1
1
0
0
0
1
4
4
5
6
1
1
1
2
0
0
0
1
2
2
2
3
1
1
1
1
0
0
0
0
2
2
3
4
1
1
1
2
0
0
0
0
4
4
5
6
2
2
2
3
0
0
1
1
3
48---30,50,60
60---30,50,60
210
236
238
264
6.2
8.35
3170
3365
1/5
1/4
1100
1100
17.25
21.56
25
25
1
1
4
5
7/8
7/8
7/8
7/8
150
175
200
225
7
8
9
10
2
2
3
3
3
4
4
5
1
1
1
1
0
0
0
0
5
6
7
8
2
2
2
3
1
1
1
1
7
9
10
11
2
3
3
4
1
1
1
2
4
4
5
6
2
2
2
3
0
0
0
0
5
5
6
7
2
2
3
3
0
0
1
1
7
9
10
11
4
4
5
5
1
1
1
1
261
295
8.75
4050
1/5
825
25.15
25
1
5
7/8
1--- 1/8
250
12
3
6
2
1
9
3
1
13
4
2
6
3
1
8
4
1
12
6
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents