DETAILED COOLING CAPACITIES
EVAPORATOR
AIR
75
Capacity
Total
MBtuh†
System
CFM
EWB
Sens
KW**
Total
72
33.13
17.60
2.01
67
30.12
21.64
2.01
875
62
27.50
25.68
2.01
57
26.93
26.93
2.01
72
33.69
18.46
2.05
67
30.64
23.04
2.05
1000
62
28.16
27.55
2.06
57
28.03
28.03
2.06
72
34.09
19.27
2.10
67
31.03
24.36
2.10
1125
62
28.94
28.94
2.10
57
28.94
28.94
2.10
Cooling Indoor
Capacity
Model
*CAP**3014A**
1.00
CAP**3017A**
1.00
CAP**3614A**
1.00
CAP**3617A**
1.00
CAP**3621A**
1.00
CNPF*3618A**
0.99
CNPH*3017A**
0.99
CNPH*3617A**
0.99
CNPV*3014A**
0.99
CNPV*3017A**
0.99
CNPV*3617A**
0.99
CNPV*3621A**
0.99
CSPH*3012A**
0.96
CSPH*3612A**
0.98
FE4ANF002
0.99
FE4ANF003
1.00
FE4ANF005
1.03
FF1ENP030
0.98
FF1ENP036
1.00
FV4BNF002
0.99
FV4BNF003
1.00
FV4BNF005
1.03
FX4CN(B,F)036
1.01
FX4CNF030
1.00
FY4ANF030
0.99
FY4ANF036
0.99
See notes on pg. 21
CONDENSER ENTERING AIR TEMPERATURES deg F
85
Capacity
Capacity
Total
MBtuh†
MBtuh†
System
Sens
KW**
Total
Total
24ACA330A30 Outdoor Section With CAP**3014A** Indoor Section
31.70
17.06
2.23
30.20
28.78
21.09
2.23
27.37
26.29
25.09
2.23
25.03
25.94
25.94
2.24
24.89
32.21
17.92
2.27
30.64
29.26
22.48
2.27
27.80
26.95
26.95
2.28
25.86
26.98
26.98
2.28
25.86
32.57
18.72
2.32
30.96
29.61
23.80
2.32
28.12
27.83
27.83
2.32
26.66
27.83
27.83
2.32
26.66
Multipliers for Determining the Performance With Other Indoor Sections
Power
Furnace Model
1.00
1.00
1.00
1.00
1.00
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.96
0.98
0.95
0.94
0.94
0.98
1.00
0.95
0.94
0.94
0.96
0.98
0.99
0.99
{{
(CONT.)
95
105
Capacity
Total
Total
MBtuh†
System
System
Sens
Sens
KW**
KW**
Total
16.49
2.47
28.59
15.90
2.75
20.50
2.48
25.87
19.89
2.76
24.47
2.48
23.75
23.75
2.77
24.89
2.48
23.76
23.76
2.77
17.34
2.52
28.98
16.74
2.80
21.89
2.52
26.25
21.27
2.80
25.86
2.53
24.67
24.67
2.81
25.86
2.53
24.67
24.67
2.81
18.14
2.56
29.26
17.54
2.84
23.20
2.57
26.54
22.57
2.85
26.66
2.57
25.40
25.40
2.85
26.66
2.57
25.41
25.41
2.85
Cooling Indoor
Model
CAP**3014A**
CAP**3614A**
CNPH*3017A**
CNPH*3617A**
CNPV*3014A**
CSPH*3012A**
CSPH*3612A**
CAP**3017A**
CAP**3617A**
CNPV*3017A**
CNPV*3617A**
CAP**3621A**
CNPV*3621A**
CNPH*3017A**
CNPH*3617A**
CSPH*3012A**
CSPH*3612A**
CAP**3017A**
CAP**3617A**
CNPV*3017A**
CNPV*3617A**
CAP**3621A**
CNPV*3621A**
17
115
Capacity
Capacity
Total
MBtuh†
MBtuh†
System
Sens
Sens
KW**
Total
Total
26.87
15.27
3.06
25.01
24.27
19.25
3.07
22.59
22.56
22.56
3.08
21.27
22.56
22.56
3.08
21.27
27.20
16.10
3.11
25.32
24.61
20.61
3.12
22.87
23.39
23.39
3.12
22.02
23.39
23.39
3.12
22.02
27.43
16.89
3.15
25.50
24.86
21.90
3.16
23.10
24.06
24.06
3.16
22.61
24.06
24.06
3.16
22.62
Capacity
Power
Furnace Model
0.99
0.97
58CV(A,X)070---12
0.99
0.94
58CV(A,X)070---12
0.98
0.94
58CV(A,X)070---12
0.98
0.94
58CV(A,X)070---12
0.98
0.96
58CV(A,X)070---12
0.96
0.92
58CV(A,X)070---12
0.97
0.93
58CV(A,X)070---12
0.99
0.94
58CV(A,X)090---16
0.99
0.95
58CV(A,X)090---16
0.98
0.94
58CV(A,X)090---16
0.98
0.94
58CV(A,X)090---16
0.99
0.95
58CV(A,X)110---20
0.99
0.94
58CV(A,X)110---20
0.98
0.96
58MVB040---14
0.98
0.96
58MVB040---14
0.96
0.94
58MVB040---14
0.97
0.93
58MVB040---14
0.99
0.94
58MVB060---14
0.99
0.94
58MVB060---14
0.98
0.94
58MVB060---14
0.98
0.94
58MVB060---14
0.99
0.95
58MVB080---14
0.98
0.94
58MVB080---14
125
Total
System
KW**
14.60
3.38
18.58
3.42
21.27
3.43
21.27
3.43
15.44
3.45
19.92
3.46
22.02
3.47
22.02
3.47
16.22
3.49
21.19
3.50
22.61
3.48
22.62
3.51