Securing And Leveling The Appliance - Quadra-Fire Expression 36 Owner's Manual

Qv36a-fb
Hide thumbs Also See for Expression 36:
Table of Contents

Advertisement

5. Attach the collar that is included with the Heat-Zone-
Gas Kit.
Figure 7.5. Heat-Zone-Gas Collar Installed.
6. Attach the insulated fl ex that is included in the Heat-
Zone-Gas kit with the provided hose clamp.
Figure 7.6. Install Insulated Flex.
7. Close the top of the appliance by bending the four pre-
cut tabs back to their original orientation as shown in
Figure 7.7.
Figure 7.7. Bend Pre-cut Tabs Down.
Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. Q • 2/10
C. Securing and Leveling the Appliance
WARNING
Fire Risk.
• Prevent contact with sagging, loose insulation.
• Do NOT install against combustible materials
such as exposed insulation, plastic and insulation
backer.
The diagram shows how to properly position, level, and
secure the appliance (see Figure 7.8). Nailing tabs are pro-
vided to secure the appliance to the framing members.
• Venting - refer to Vent Clearances and Framing (Section
6) for hole location.
• Place the appliance into position.
• Level the appliance from side to side and front to back.
• Shim the appliance as necessary. It is acceptable to use
wood shims.
• Bend out nailing tabs on each side.
• Keep nailing tabs fl ush with the framing.
• Secure the appliance to the framing by using nails or
screws through the nailing tabs.
WARNING
Fire Risk.
• ALWAYS maintain specifi ed
clearances around the appliance.
• Do NOT notch into the framing around the appliance spacers.
Failure to keep insulation, framing or other material away from
the appliance may cause fi re.
STEEL BACK
SUPPORT
Figure 7.8 Proper positioning, leveling and securing of an
appliance
COVER PLATES