ISDN Wide Area Network Design: Dry Creek Joint Elem. School District
ISDN Configurations
Remote Router
Basic configuration:
SNMP enabled, and Telenet enabled. The remote-site router is the an-
swerer and causes the terminal adapter to wait to answer the call when
the router is booted and its DTR goes high.
HP Router FR ISDN Circuit Configuration:
Circuit Name:
Auto Enable:
Quality of Service:
Circuit Type:
Min Frame Spacing:
Connect when:
Connect retry count:
Connect wait time (sec.):
Delay after connect failure (min.):
1
It was discovered during testing that this parameter should be set to zero to ensure
that the "answer" end point is ready to reconnect immediately in the event of a
power loss or component failure.
Remote Office Terminal Adapter (TA)
AT&T 7500B Data Module operating in synchronous DCE mode acting as the
answerer.
Configuration:
Set Autodial = NO
Set busy out = OFF
Data Rest = OFF
Set DTR = FOLLOW
Set Duplex = FULL
Set Mode = CS
Set Speed = 64000
3-38
Host-only bridging enabled, TFTP enabled,
WAN1
Yes
LLC 1 (datagram)
ISDN Manual adapter
2
Circuit is enabled
3
1
0
.5